Remove the screws connecting the outer case with
motor support, isolation plate and chassis; lift the
outer case upwards; loosen the clasps of outer
case with right side plate and left side plate, and
then remove the outer case.
Remove the screws connecting the right side plate
with electric box assy, valve support, chassis and
condenser side plate, and then remove the right
side plate.
Remove the screws connecting the
left side plate
with chassis, and then remove the
left side plate.
Steps
Procedure
left side plate
outer case
3. Remove right&
left
side plate
right side plate
a
b
b
112
Installation and Maintenance
Service Manual
Remove the nut fixing axial flow blade and then
remove the blade.
Remove the 6 screws fixing the motor and then
remove the motor.
Remove the 2 screws connecting the motor support
and chassis, and then loosen the stopper to remove
the motor support.
Remove the screws fixing the electric box sub-assy;
loosen the wire bundle; pull out the wiring terminals
and then pull the electric box upwards to remove it.
Steps
Procedure
5. Remove
electric box
4. Remove axial flow blade
axial flow fan
motor support
fan motor
electric box