44
In older versions of GSM modems without implemented protection procedures the SIM card
may get blocked after 3 failed attempts and the only method of unblocking it is to supply
the right PUK code. Unfortunately this cannot be performed using the MT-301/302/303/304
module.
The PUK code may by inserted only after taking the SIM card out of module and placing it in
a standard GSM mobile phone. The phone will demand entering of PUK code at power-up.
Entering correct PUK-code unblocks the card and resets PIN fault counter making the card
operational.
9. Technical data
9.1. General
Dimensions (height x width x length)
124x63x30 mm
Weight 100
g
Mounting method
DIN rail 35mm
Operating temperature
1)
0
0
... +55
0
C
Protection class
IP40
1)
Operating temperatures below 0
o
C are not recommended because of LI-Polymer battery requirements
9.2. GSM/GPRS Modem
WISMO Quick 2406B:
Modem type
WISMO Quick 2406B
GSM
Dual Band GSM/GPRS module EGSM900/1800
Frequency range
(EGSM 900 MHz)
Transceiver: from 880 MHz to 915 MHz
Receiver: from 925 MHz to 960 MHz
Peak transmitting power
(EGSM 900 MHz)
33 dBm (2W) – class 4 station
Frequency range
(EGSM 1800 MHz)
Transceiver: from 1710 MHz to 1785 MHz
Receiver: from 1805 MHz to 1880 MHz
Peak transmitting power
(EGSM 1800 MHz)
30 dBm (1W) – class 1 station
Modulation 0.3
GMSK
Channel spacing
200 kHz
Antenna
50
WISMO Quick 24 PLUS:
Modem type
WISMO Quick Q24 Plus
GSM
Multiband GSM module (900/1800 or
850/1900)MHz
GPRS Class
10
Frequency range
(EGSM 900 MHz)
Transceiver: from 880 MHz to 915 MHz
Receiver: from 925 MHz to 960 MHz
Frequency range
(GSM 850 MHz)
Transceiver: from 824 MHz to 849 MHz
Receiver: from 869 MHz to 894 MHz
Peak transmitting power
(EGSM 900 MHz & GSM 850 MHz)
33 dBm (2W) – class 4 station