35
7.2.5.3.1.4. Unit
Function
-
allows choosing unit of timer counting period value
Data type
- selection
list
List
-
Second
Minute
Hour
Default
value
-
Second
Comments
-
if synchronization is activated new parameter Start becomes
available. This parameter defines RTC synchronization time.
7.2.5.3.2. ATR timer
ATR timer is a special purpose timer used for cyclic module resets. This mechanism
allows circumventing the problem of MT-30x's build-in modem crashes appearing in
some mobile networks in specific, rare cases. There is also possibility of resetting the
module on demand by sending to module SMS message that reads
#RS
. A reset will be
done under condition of the presence of the module in a GSM network, and sending
SMS from the number that is on the lists of authorized telephone numbers.
7.2.5.3.2.1. Start
Function
-
defines time of start of ATR timer.
Data type
- time
[HH:mm]
Range
-
0:00 - 23:59
Default
value
- 0:00
Comments
- n/a
7.2.5.3.2.2. Value
Function
-
defines period of module resets by ATR timer
Data type
- selection
list
List
-
0
timer inactive
6h
6 hour period
12h
12 hour period
24h
24 hour period
Default
value
-
0
Comments
- n/a
7.2.6. Rules
Rules group contains lists of transmission tasks performed by internal program when
criteria defined in rules are met. Tasks are divided into three groups:
rules concerning transmission of SMS messages
rules concerning transmission of data
rules concerning making CLIP calls