60
ASSEMBLY AND INSTALLATION
inVENTer
®
iV14R/iV14V ventilation system
•
Installation and operating instructions
TIP
Make sure that you it the dust ilter correctly to prevent the ventilation unit malfunctioning.
Ö
Ö
Inner cover Flair V-233x233 is itted.
Removing inner cover R-D290/V-284x284/V-220x200/ Flair V-233x233
Requirements:
Thermal accumulator/fan is itted.
The fan's start direction is set.
►
Remove the inner cover in the reverse sequence.
Ö
Ö
Inner cover is removed.
►
Using an hex key (8), turn the screws and
washers (7) into the ixing elements (6) on the
wall sleeve.
6
7
8
►
Insert the dust ilter (10) into the inner cover
base plate (9).
Make sure that
the ilter ring (12) is pressed
irmly between the ixing lugs (green arrows)
and the inner rim (13) on the inner cover base
plate (9).
Make sure that
the tab (11) on the
ilter ring (12) points into the interior.
9
12
11
13
10
►
Place the panel (15) on the four spacers (14).
Make sure that
the printed marker arrows on
the panel's back side are pointing upwards.
Make sure that
you press the locking
lugs (green arrows) on the spacers (12)
inwards.
►
Push the inner cover panel (15) onto the
spacers (14).
All spacers mus
t click into place.
14
15