background image

www.inventer.eu

inVENTer Connect

1505-0036
1505-0037

Quick Guide

Set-up

Содержание 1505-0036

Страница 1: ...www inventer eu inVENTer Connect 1505 0036 1505 0037 Quick Guide Set up ...

Страница 2: ... the controller may only be performed by qualified personnel Qualified personnel within the meaning of the safety notices in this documentation are persons who are authorised to install put into operation and identify equipment systems and circuits in accordance with established safety procedures Symbols used in this documentaion NOTICE Indicates a direct or possible risk of property damage due to...

Страница 3: ...Download Manual Installation 230 V AC OFF 230 V AC ...

Страница 4: ...a the Connect inner covers while the sensor system sends the sensor data to the controller The wireless control unit has an information display and offers quick access The controller also serves as the system interface for the inVENTer Mobile app Bluetooth interface BLE The Connect inner cover is a wireless interiour termination and replaces the standard inner covers of the iV Smart iV14 Zero iV C...

Страница 5: ...nect switching contact is a wireless interface for the integration of safety devices while simultaneously operating the ventilation system with fireplaces In addition to the fixed system components the free app inVENTer Mobile is required for complete control and programming The system can also be put into operation without the app and can be controlled on a basic level via the wireless controller...

Страница 6: ... Connect outdoor humidity temperature sensor 5040 0033 SK19 Connect switching contact 5040 0039 4 Initial set up Sensor keys for quick operation of the ventilation unit Navigation keys Navigate and change values setting of time Mode key Change between user specific settings complete settings Selection key Confirmation of settings Auto Pause Boost key Set ventilation units globally or by zone in ve...

Страница 7: ...o the time and date setting X Press the mode key 3 to confirm the selection X Establish the power connection Ö The controller performs firmware and hardware checks for the system the LED flashes RED GREEN and BLUE during this process 1 Ö After a successful firmware and hardware check the LED lights up WHITE 2 Ö The controller changes to the radio channel setting Step 1 Connecting to mains power Th...

Страница 8: ...ing is flashing 1 X Press the navigation keys to set the current year X Press the mode key Afterwards the month setting is flashing 2 X Press the navigation keys to set the current month X Press the select key Finally the day setting is flashing 3 X Press the navigation keys to set the current day X Press the mode key Optional Step 3 Time and date setting A flashing value setting on the controller...

Страница 9: ...ation Ö Initial set up of the Easy Connect e16 controller is executed Up to 16 system components ventilation units Connect inner covers sensors switching contact can be paired with the Easy Connect e16 controller and thus be integrated into the inVENTer Connect controller platform To do so activate component pairing on the controller activate all system components to be integrated complete compone...

Страница 10: ...ark the sequence of the paired components with the supplied numbers X Mark the first paired component here e g the inner cover with the number 1 X Before activating an component mark the paired devices consecutively in the pairing order Step 2 Activating components to be integrated Whlie the white LED flashes on the Easy Connect e16 controller approx 5 minutes all components to be integrated must ...

Страница 11: ...rate button inside housing FTS19 Connect outdoor button inside the housing FTS19 Connect indoor button on the underside of the housing CS2 Connect SK19 Connect button on the housing s front side Ö The LED lights up 1 X Press and hold the push button again until the LED lights up GREEN approx 3 s 2 Ö The component is ready for pairing with the controller Ö The LED on the component flashes GREEN dur...

Страница 12: ...ystem components inner covers external sensors switching contact send to the controller Ö The system operates in the default profile factory settings Display screen Time Ventilation profile Default can be modified Ventilation level Ventilation mode Heat recovery Unidirectional ventilation Pause Off System display via sensor technology transmitted values to the controller system Status 1 25 Air flo...

Страница 13: ... symbol II flashes Ö The locking arm swivels to the right X Confirm with the selection key X Mount the cover by sliding the lower lugs into the guide and pressing the cover against the Connect inner cover X Putting the ventilation unit into operation again Press the pause key on the controller until the automatic symbol flashes The automatic closing flaps are opened again The ventilation units sta...

Страница 14: ...e app must be given location access X Download the inVENTer Mobile app to your mobile device Ö After successful installation of the app the corresponding icon appears on the screen X Touch the icon of the inVENTer Mobile app on the screen of your mobile device Ö The start screen appears X Touch the START button Inventer Mobile Welcome to inVENTer Mobile Set up your new inVENTer product in short an...

Страница 15: ...ey until the LED turns BLUE Ö The controller and mobile device connect Ö The LED on the controller flashes BLUE X While the LED on the controller is flashing BLUE press the Connect button on your mobile device CONGRATULATIONS You have just completed the setup of your inVENTer The app allows you to set the unit s ventilator speed and automatic functions COMPLETE SETUP CANCEL SETUP Ö A message appea...

Страница 16: ...hey can be assigned to individual ventilation zones X Press the area with the available controller on the mobile device Ö A window with the possible menus appears Ventilation zone overview Device overview Advanced settings X Select the Device overview Ö All paired devices and their status are displayed Enter the new product name Easy Connect e16 ABBRECHEN OK CANCEL Easy Connect e16 Controller Devi...

Страница 17: ... and rename it if necessary X Press the ventilation zone button and change the ventilation zone assignment Text in gey ventilation zone cannot be changed The menu item Device overview is described in the inVENTer Connect controller platform s detailed operating instructions 5022 0006 X Press the arrow in the upper left corner of a display window to return to the menu window The arrow always takes ...

Страница 18: ...indow appears in which the properties of this ventilation zone are displayed X Press the profile symbol Ö A selection window with the possible ventilation profiles appears X Press a ventilation profile to select it for the respective zone Advanced settings Device overview Ventilation zone overview Easy Connect e16 Easy Connect e16 Ventilation zone 1 Ventilation zone overview 25 8 C 24 9 Default Cu...

Страница 19: ... C 24 9 Current ventilator power level 1 Ventilation zone 2 Override 18 4 C 39 2 Bedroom Current ventilator power level 3 Ventilation zone 3 Override 22 8 C 33 7 Kitchen Current ventilator power level 4 Ventilation zone 4 Override 24 3 C 55 4 Bathroom For these settings follow the menu navigation on your mobile device or the description in the inVENTer Connect controller platform s detailed operat...

Страница 20: ... for possible repeaters X Press the Device overview button X Press the Radio signal weak symbol of the component that needs signal amplification repeater necessary Advanced settings Device overview Ventilation zone overview Easy Connect e16 26 C 26 Device 5 25 4 C 22 1 20 4 C 44 1 Device 0 Device 1 Device 2 Device 6 Ventilation zone 1 Ventilation zone 1 Ventilation zone 1 Ventilation zone 1 Ventil...

Страница 21: ...warranty or guarantee claim contact your local distributor or factory representative For technical support contact our service staff 49 0 36427 211 0 info inventer de X Select the device that is to act as a signal amplifier from the suggestions Radio Performance Repeater slave identified Select one to enable Device 2 M Signal strength 75 dB D Signal strength 70 dB M Signal strength 74 dB D Signal ...

Страница 22: ......

Страница 23: ......

Страница 24: ...o in combinazione con il Istruzioni d uso originali dei controllori inVENTer Leggere attentamente le istruzioni originali e osservare le istruzioni di sicurezza Ce document est valide uniquement en conjonc tion avec les instructions d origine du regulateur inVENTer Pri re de lire attentivement les instructions d origine et observez les consignes de sécurité Tento dokument je platný pouze ve spojen...

Отзывы: