A4
OPERATION
Equipment Description
Charging
1) Charging of a permanently installed battery in a vehicle
a) Before connecting or disconnecting the battery leads, the power cord should be removed from the mains.
b) Check polarity of battery post. A positive (“+”) battery post usually has a larger diameter than a negative (“-”) post.
c) Identify the pole of battery which is connected to the chassis (earth). Normally the negative terminal is connected
to the chassis.
d) Charging of negative earthed battery:
• Make sure the black wire
㉖
(“-” pole connection) has not contact with the fuel line or the battery.
• Connect the red wire
㉕
(“+”) to the positive (“+”) pole of the battery and the black wire
㉖
(“-“) to the vehicle
chassis.
e) Charging of positive earthed battery:
• Make sure the red wire
㉕
(“+” pole connection) has no contact with the fuel line or the battery.
• Connect the black wire
㉖
(“-”) to the negative (“-”) pole of the battery and the red wire
㉕
(“+“) to the vehicle
chassis.
2) Charging of a battery not connected to a vehicle
a) Before connecting or disconnecting the battery leads, the power cord should be removed from the mains.
b) Connect the red wire
㉕
(“+”) to the positive (“+”) pole of the battery and the black wire
㉖
(“-“) to the negative (“-“)
pole.
In case of reverse polarity connection red LED
⑨
indicate error mode. This function would not work in
Supply Mode. Error indication light
⑨
would be also shown if charge mode is initiated without connecting the
battery to the battery leads.
3) Charging with eyelet terminals (Permanent connection to the vehicle battery)
a) Before connecting or disconnecting the battery leads, the power cord should be removed from the mains.
b) Connect the red wire
㉒
(“+”) to the positive (“+”) pole of the battery and the black wire
㉓
(“-“) to the negative
(“-“) pole.
a) Indication:
BOOST