background image

A4

OPERATION

Equipment Description

Charging

1) Charging of a permanently installed battery in a vehicle
    a) Before connecting or disconnecting the battery leads, the power cord should be removed from the mains.
    b) Check polarity of battery post. A positive (“+”) battery post usually has a larger diameter than a negative (“-”) post.
    c) Identify the pole of battery which is connected to the chassis (earth). Normally the negative terminal is connected 
        to the chassis.
    d) Charging of negative earthed battery:

        • Make sure the black wire 

 (“-” pole connection) has not contact with the fuel line or the battery.

        • Connect the red wire 

  (“+”) to the  positive (“+”) pole of the battery and the black wire 

 (“-“) to the vehicle 

           chassis.
    e) Charging of positive earthed battery:

        • Make sure the red wire 

 (“+” pole connection) has no contact with the fuel line or the battery.

        • Connect the black wire 

 (“-”) to the  negative (“-”) pole of the battery and the red wire 

 (“+“) to the vehicle   

           chassis.
2) Charging of a battery not connected to a vehicle
     a) Before connecting or disconnecting the battery leads, the power cord should be removed from the mains.
     b) Connect the red wire 

(“+”) to the  positive (“+”) pole of the battery and the black wire 

(“-“) to the negative (“-“) 

         pole.
         In case of reverse polarity connection red LED          

⑨ 

indicate error mode. This function would not work in 

         Supply Mode. Error indication light         

⑨ 

would be also shown if charge mode is initiated without connecting the 

         battery to the battery leads.
3) Charging with eyelet terminals (Permanent connection to the vehicle battery)
     a) Before connecting or disconnecting the battery leads, the power cord should be removed from the mains.
     b)  Connect the red wire 

  (“+”) to the  positive (“+”) pole of the battery and the black wire 

  (“-“) to the negative 

          (“-“) pole.

a) Indication:

BOOST

Содержание SC-7

Страница 1: ...SC 7 For Lead acid batteries 14 230Ah 12V 14 120Ah 24V BATTERY CHARGER BATTERY CHARGER SWITCH MODE SWITCH MODE User s Manual And Guide To Professional Battery Charging ...

Страница 2: ...aration of Compliance 11 Rescuing Drained Battery 7 Abnormality Protection 8 Overheating Protection 8 Index Index For Your Safety 2 Product Feature 2 Product Safety Feature 2 Contents 2 Safety Information 2 Locate Charger 3 Battery Type Settings 3 Operation 4 7 Charging 4 Equipment Description 4 Indication 4 5 Component Description 5 Select Charging Mode 5 Reset Deleting Settings 5 Identification ...

Страница 3: ...onnection to the battery unless charging mode has been selected This embedded feature eliminates the possibility of a spark that often appears during connections Fully controlled by internal MCU Micro Computer Unit which makes it faster powerful reliable and smarter It detects the state of charge of the battery plugged into it and initiates charging Dust and splash proof IP65 approval Approved for...

Страница 4: ...y range from 14 230Ah in normal condition To recover severely discharged batteries due to stratified acid this mode is useful High voltage 17V max at 1 5A is applied for a maximum period of 3 hours A fully charged battery gives faster result High voltage may cause some water loss For optimal efficiency and minimum risk to vehicle s boat s electronics battery must be disconnected Do not cover the c...

Страница 5: ...onnection has no contact with the fuel line or the battery Connect the black wire to the negative pole of the battery and the red wire to the vehicle chassis 2 Charging of a battery not connected to a vehicle a Before connecting or disconnecting the battery leads the power cord should be removed from the mains b Connect the red wire to the positive pole of the battery and the black wire to the neg...

Страница 6: ...ttery or deep discharged 24V battery INVATEC SC 7 charger smartly identifies correct nature of battery and provides appropriate course of action Once the selection button is pressed charging LED shall flash on off cycle in 0 5 second Within 1 2 minutes the embedded MCU would detect change in battery voltage If battery voltage remains at original value or rises to a higher level system would treat ...

Страница 7: ... The Trickle current is now available to battery for maintenance MODE MODE 3 14 4V 7A This mode is suitable for charging 12V batteries with capacity range from 14 230Ah in normal conditions Connect the output terminals of the charger to the battery with right polarity Connect the power cord to the power outlet to begin charging Press the selection button to select Mode 3 LED 3 After executing this...

Страница 8: ...r outlet to begin charging Press the selection button to select Mode 5 LED 6 After executing this operation the corresponding LED display will light up If no further process is activated the electronic system will automatically start the maintenance charging at constant voltage 13 6V 0 25V with a output current of 5 0A 10 by indicating flashing on off cycle in one second The charger has overload p...

Страница 9: ...to select 1 5A RMS max 75 28 8V 0 25V or 29 4V 0 25V or 14 4V 0 25V or 14 7V 0 25V or 13 6V 0 25V or 16 5V 0 25V 7 0A 10 or 5 0A 10 or 3 0A 10 or 1 5A 20 5 mA Max 150mV 0 3A 20 C to 50 C 4 F to 122 F Reduced output power at higher temperature Seven step fully automatic switch mode with maintenance charging 12V 24V Lead acid batteries WET MF AGM and GEL 14 230 Ah for 12V 14 120Ah for 24V 201 91 51 ...

Страница 10: ...stant current of 7 0A until the voltage reaches to 12 8V b Medium Rate Charging Charger delivers constant current of 5 0A until the voltage reaches to 13 9V at this level constant current is 3 5A until voltage reaches to 14 0V Finally charger delivers 3 0A current until voltage reaches to 14 1V at which point the charger switches to Absorption phase Since current is not delivered at highest consta...

Страница 11: ...battery to ground Charger light is on but battery does not charge properly a The battery may be defective or of oversize b The battery has a excessive current draw battery must be replaced INVATEC SC 7 is fully interactive charger which adjusts itself to changing current and voltage requirement to charge and maintain the battery 4 Trickle Charge Battery is fully charged and ready to use The batter...

Страница 12: ... Please refer to product drawing Equipment INVATEC SC 7 charger is supplied with two detachable and interchangeable colour coded lead sets one with clamps for bench charging and other with eyelet terminals Ø6 3mm with in line battery protection plug in fuse 10A for permanent attachment to the battery posts to allow quick connection disconnection through snap connector Declaration of Compliance Tes...