Invacare® TDX® SP2 Series
Failure to use the correct battery size and/or voltage
may cause damage to your wheelchair and give
you unsatisfactory performance. The warranty and
performance specifications contained in this manual
are based on the use of deep cycle gel cell batteries.
Invacare strongly recommends their use as the
power source for this unit.
Carefully read battery/battery charger information prior to
installing, servicing or operating your wheelchair.
1.
Position battery on ground/flat surface as shown below.
2.
Visually inspect the battery to ensure proper polarity:
FOR WHEELCHAIRS USING 22NF BATTERIES
Batteries with terminal configuration (POSITIVE
A
on
the left and NEGATIVE
B
on the right) as shown below
MUST be used. Batteries that have the reverse terminal
configuration MUST not be used - otherwise injury and
damage may occur.
Terminals must have a cross hole
C
in them as shown
below.
PROPER BATTERIES TO USE
DO NOT USE THIS TYPE
OF BATTERY
Fig. 7-2
Fig. 7-3
FOR WHEELCHAIRS USING GP24 BATTERIES
Batteries with terminal configuration (POSITIVE
A
on
the right and NEGATIVE
B
on the left) as shown below
MUST be used. Batteries that have the reverse terminal
configuration MUST not be used - otherwise injury and
damage may occur.
Terminals must have a cross hole
C
in them as shown
below.
46
60101877-B