Invacare IRCPF16AW Скачать руководство пользователя страница 2

©2017 Invacare Corporation
All rights reserved. Republication, duplication or modification in whole or in part is prohibited
without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks
are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.
Making Life’s Experiences Possible is a registered trademark in the U.S.A.

Содержание IRCPF16AW

Страница 1: ...Invacare PreciseRx Pediatric Flowmeter IRCPF16AW en User Manual This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference 0120...

Страница 2: ...whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unles...

Страница 3: ...ety 7 2 1 General Guidelines 7 3 Setup 11 3 1 Handling 11 3 2 Typical Setup 11 3 3 Setup Without a Humidifier Bottle 13 3 4 Setup With a Humidifier Bottle 14 3 5 Setting the Flowrate on the Pediatric...

Страница 4: ...or both IMPORTANT IMPORTANT indicates a hazardous situation that could result in damage to property if it is not avoided Gives useful tips recommendations and information for efficient trouble free us...

Страница 5: ...an described in the specifications and intended use sections of this manual 1 3 Indications for Use To provide supplemental oxygen to patients with low flow prescriptions in a non acute setting 1 4 Co...

Страница 6: ...to a pediatric patient through an externally connected administration accessory a pediatric nasal cannula Oxygen gas output can be delivered to the patient in adjustable flow rates in the continuous...

Страница 7: ...h as cannulas or tanks DANGER Risk of Death Injury or Damage from Fire Textiles oil or petroleum substances grease greasy substances and other combustibles are easily ignited and burn with great inten...

Страница 8: ...act a technician or Invacare for repair This product is intended to be set up by adults or under adult supervision only after reading and understanding the instructions and warnings of this user manua...

Страница 9: ...ce oxygen due to power failure or device malfunction Contact your provider for a backup source of oxygen for a pediatric patient Do not connect the input of the device to any other oxygen delivery dev...

Страница 10: ...servicing to qualified service personnel There are no user serviceable parts CAUTION Risk of Damage To prevent damage from liquid ingress If the device is not working properly if it has been dropped...

Страница 11: ...a with this device Place the pediatric nasal cannula on patient only after all tubing connections have been made Possible water feedback through the tubing could occur in this sequence is not followed...

Страница 12: ...stand on table top 4 Turn the Pediatric Flowmeter knob counterclockwise to the fully open position 5 Allow concentrator to run a minimum of 30 minutes to ensure proper concentration level Check and r...

Страница 13: ...ect a 2 1 m 7 ft oxygen tubing E from the output fitting C of the concentrator D to the input fitting B of the Pediatric Flowmeter A 2 Connect a 7 6 m 25 ft maximum length oxygen tubing not shown to t...

Страница 14: ...bottle H manufacturer for instructions on filling and connecting to oxygen tubing 3 After filling the humidifier bottle with water place it in the humidifier compartment on the Invacare concentrator D...

Страница 15: ...2 When adjusting the flow center the ball A of the Pediatric Flowmeter B with the line of the prescribed flowrate When viewing from the proper angle the graduation lines on the front and the back of...

Страница 16: ...re manufacturer Follow local governing ordinances and recycling plans regarding disposal of the device or accessories normally used in operation The device does not generate waste or residue in operat...

Страница 17: ...DJUSTABLE IN INCREMENTS 50 cc min 1 16 L min FLOW ACCURACY 10 of full scale WIDTH 11 94 cm 4 7 in HEIGHT 14 48 cm 5 7 in DEPTH 14 48 cm 5 7 in WEIGHT 0 8 kg 1 86 lb SHIPPING WEIGHT 1 1 kg 2 40 lb OPER...

Страница 18: ...nty Terms and conditions of the warranty are part of the general terms and conditions particular to the individual countries in which this product is sold Contact information for your local Invacare o...

Страница 19: ...San s r l Via dei Pini 62 I 36016 Thiene VI Tel 39 0445 38 00 59 Fax 39 0445 38 00 34 italia invacare com www invacare it Nederland Invacare AE Galvanistraat 14 3 NL 6716 BZ Ede Tel 31 0 318 695 757...