Invacare H720T4C Скачать руководство пользователя страница 3

I

en

I

1 Introduction

This user manual contains important information about the
handling of the product. To ensure safety when using the
product, read the user manual carefully and follow the safety
instructions.

Invacare reserves the right to alter product specifications
without further notice.

Before reading this document, make sure you have the latest
version. You find the latest version as a PDF on the Invacare
website.

If you find that the font size in the printed document is
difficult to read, you can download the PDF version from the
website. The PDF can then be scaled on screen to a font size
that is more comfortable for you.

In case of a serious incident with the product, you should
inform the manufacturer and the competent authority in
your country.

2 Warranty Information

We provide a manufacturer’s warranty for the product
in accordance with our General Terms and Conditions of
Business in the respective countries.

Warranty claims can only be made through the provider from
whom the product was obtained.

3 Compliance

Quality is fundamental to the company’s operation, working
within the disciplines of ISO 13485.

This product features the CE mark, in compliance with the
Medical Device Regulation 2017/745 Class I. The launch date
of this product is stated in the CE declaration of conformity.

We are continuously working towards ensuring that the
company’s impact on the environment, locally and globally, is
reduced to a minimum.

We only use REACH compliant materials and components.

3.1 Product-specific Standards

The product has been tested and conforms to EN 12182
(Assistive products for persons with disability) and related
standards. For further information about local standards and
regulations, contact your local Invacare representative. See
addresses at the end of this document.

4 Service Life

The expected service life of this product is three years when
used daily and in accordance with the safety instructions,
maintenance intervals and correct use, stated in this manual.
The effective service life can vary according to frequency and
intensity of use.

5 Limitation of Liability

Invacare accepts no liability for damage arising from:

Non-compliance with the user manual

Incorrect use

Natural wear and tear

Incorrect assembly or set-up by the purchaser or a third
party

Technical modifications

Unauthorised modifications and/or use of unsuitable
spare parts

6 Safety

6.1 Safety Information

WARNING!
Risk of Serious Injury or Damage

Improper use of this product may cause injury
or damage.

– If you are unable to understand the warnings,

cautions or instructions, contact a health care
professional or provider before attempting to
use this equipment.

– Do not use this product or any available

optional equipment without first completely
reading and understanding these instructions
and any additional instructional material such
as user manual, service manual or instruction
sheet supplied with this product or optional
equipment.

WARNING!
Risk of Falling!

– Do not use if defective.
– Do not make any unauthorized alterations or

modifications to the product.

– Do not use in shower.
– Keep product away from open flames.
– Do not place smoldering cigarettes on the

product.

– Do not stand on this product.
– Do not use as a climbing aid.
– Do not lift the product when under load.
– Only use the toilet chair on a level ground and

indoors.

WARNING!
Risk of Tipping!

– Never stand on the footrests.
– Do not lean excessively forwards.

CAUTION!
Risk of Burning Skin!

The product components can heat up when
exposed to external sources of heat.

– Do not expose the product to direct sunlight

before use.

WARNING!

– Before first use, clean the product thoroughly.
– Before every use, check the product for damage

and ensure that it is securely assembled.

CAUTION!
Risk of Injury

Non-original or wrong parts may affect the
function and safety of the product.

– Only use original parts for the product in use.
– Due to regional differences, refer to your

local Invacare catalog or website for available
options or contact your Invacare distributor. See
addresses at the end of this document.

6.2 Labels and Symbols on the Product (Fig. 6)

A

Manufacturer

F

Production date

B

European
Conformity

G

Medical Device

1646733-B

3

Содержание H720T4C

Страница 1: ...are Cascata H720T4C en Mobile Toilet Chair User Manual 3 de Mobiler Toilettenstuhl Gebrauchsanweisung 5 fr Chaise toilette mobile Manuel d utilisation 9 it Sedia da toilette mobile Manuale d uso 12 es...

Страница 2: ...Invacare Cascata Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 2 1646733 B...

Страница 3: ...manual The effective service life can vary according to frequency and intensity of use 5 Limitation of Liability Invacare accepts no liability for damage arising from Non compliance with the user manu...

Страница 4: ...ests D on both sides through the lateral holes K into the attachment pins L Fig 4 5 Swivel both footrests to the front Adjust the height of the footrests Fig 5 1 Pull up the lever O and release the fo...

Страница 5: ...recycling facility at its end of life Disassemble the product and its components so the different materials can be separated and recycled individually The disposal and recycling of used products and...

Страница 6: ...dieses Produkts kann zu Verletzungen oder Sachsch den f hren Falls Ihnen die Warnungen Sicherheitshinweise und Anweisungen unverst ndlich sind wenden Sie sich an einen Arzt oder den Anbieter bevor Sie...

Страница 7: ...en Sie beide Fu auflagen nach vorne Stellen Sie die H he der Fu auflagen ein Abb 5 1 Ziehen Sie den Hebel O nach oben und l sen Sie die Fu auflage indem Sie sie anheben 2 L sen Sie Schraube und Mutter...

Страница 8: ...halts bliches Desinfektionsmittel Trocknen Das Produkt an der Luft trocknen lassen 13 Wiederaufbereitung Dieses Produkt ist f r die wiederholte Verwendung geeignet Um das Produkt f r einen neuen Benut...

Страница 9: ...uotidiennement et dans le respect des consignes de s curit des intervalles de maintenance et avec une utilisation correcte comme indiqu dans le pr sent manuel La dur e de vie effective peut varier en...

Страница 10: ...t est utilis comme pr vu Poids maximal de l utilisateur 130 kg 10 Montage du produit Fig 2 5 ATTENTION Risque de coincement Proc dez avec pr caution lors du montage 1 Guidez le tube de dossier C des d...

Страница 11: ...n contact avec des fluides corporels quels qu ils soient avant de l utiliser pour un nouvel utilisateur Instructions de nettoyage IMPORTANT Nettoyez le produit la main Temp rature maximale de nettoyag...

Страница 12: ...mponenti conformi alla direttiva REACH 3 1 Standard specifici per il prodotto Il prodotto stato testato ed conforme a EN 12182 Prodotti di assistenza per disabili e agli standard correlati Per ulterio...

Страница 13: ...e o fianchi Se utilizzato senza assistente gli utilizzatore devono essere in grado di mantenere l equilibrio Indicazione Mobilit ridotta o limitata ad esempio gambe e o fianchi o problemi di equilibr...

Страница 14: ...applicate Prima di utilizzare il prodotto assicurarsi sempre che sia completamente asciutto Intervalli di pulizia IMPORTANTE La pulizia e la disinfezione regolari consentono di assicurare il regolare...

Страница 15: ...to lleva la marca CE en cumplimiento con el Reglamento 2017 745 sobre productos sanitarios de clase 1 La fecha de lanzamiento de este producto figura en la declaraci n de conformidad de la CE Trabajam...

Страница 16: ...hada con asiento de inodoro y cuatro ruedas con freno Se puede colocar bajo el asiento una cubeta de inodoro con tapa 8 Contenido de la entrega Fig 1 A Respaldo B Reposabrazos 2x premontados C Chasis...

Страница 17: ...eza y desinfectantes empleados deben ser eficaces compatibles entre s y deben proteger los materiales que se van a limpiar Nunca utilice fluidos corrosivos lcalis cidos etc ni productos de limpieza ab...

Страница 18: ...do site A imagem do PDF pode ser ajustada no ecr para um tamanho de tipo de letra que lhe seja mais c modo Em caso de incidente grave com o produto deve informar o fabricante e as autoridades competen...

Страница 19: ...te os endere os no final deste documento 6 2 Etiquetas e s mbolos no produto Fig 6 A Fabricante F Data de produ o B Conformidade Europeia G Dispositivo m dico C Para utiliza o apenas em terreno plano...

Страница 20: ...o Para remover a sanita repita o passo 1 pela ordem inversa A sanita pode ser levantada e transportado pela respetiva pega 12 Manuten o 12 1 Informa es gerais sobre manuten o Se as instru es de limpez...

Страница 21: ...cht voor om productspecificaties zonder voorafgaande kennisgeving te wijzigen Controleer voordat u dit document leest of u de juiste versie hebt U vindt een pdf bestand met de laatste versie op de Inv...

Страница 22: ...ebruik op schade en controleer of het stevig is gemonteerd LET OP Gevaar voor lichamelijk letsel Niet originele of verkeerde onderdelen kunnen de werking en veiligheid van het product nadelig be nvloe...

Страница 23: ...zijkant of klap de voetplaten omhoog voordat iemand plaatsneemt in of opstaat uit de rolstoel De ondersteek plaatsen verwijderen De ondersteek kan met of zonder deksel worden geplaatst verwijderd 1 P...

Страница 24: ...fvalverwerkingsstation te brengen Haal het product en de onderdelen ervan uit elkaar zodat de verschillende materialen afzonderlijk kunnen worden gerecycled Gebruikte producten en verpakkingen moeten...

Страница 25: ...Notes...

Страница 26: ...Notes...

Страница 27: ...Notes...

Страница 28: ...mp Mobility Patam enkatu 5 33900 Tampere Puhelin 09 35076310 info campmobility fi www campmobility fi Sverige Invacare AB Fagerstagatan 9 S 163 53 Sp nga Tel 46 0 8 761 70 90 Fax 46 0 8 761 81 08 swed...