42
7.8
Error Codes and Diagnostic Codes
FLASH
CODE
FAULT
EFFECT
Comments
1
User error or drive
motors overloaded
Stops driving
•
Ensure that the joystick is in the neutral
central position (simply release the
joystick) and switch on again.
•
Drive motors overloaded. Shut
electronics down and then switch on
again. If the driving power is still reduced,
wait a few minutes.
2
Battery error
Stops driving
•
Check battery and supply cable.
•
Charge batteries. If you switch the
wheelchair off for a few minutes, the
batteries can often recharge to such an
extent that a short run is still possible.
However, you should only do this in an
emergency, as this causes the batteries
to discharge excessively.
•
Replace batteries
3
Fault on left-hand
motor (M2)
Stops driving
•
Check motor cable and connecting plugs.
•
Check motor.
4
Fault on right-hand
motor (M1)
Stops driving
•
Check motor cable and connecting plugs.
•
Check motor.
5
Error on left-hand
(M2) wheel lock
Stops driving
•
Check cable and connecting plugs.
•
Check brake.
6
Error on right-hand
(M1) wheel lock
Stops driving
•
Check cable and connecting plugs.
•
Check brake.
Содержание Dragon Vertic
Страница 1: ...Invacare Dragon Vertic Electric Wheelchair User Manual...
Страница 49: ...49 Loosen the screws 1 using the Allen key Set the foot plate to the desired height Re tighten the screws...
Страница 69: ...69...
Страница 99: ...99 Order No of this Manual 1451170 DOC Release Date 25 10 05 English...