Troubleshooting and fault elimination
INTORQ | BA 14.0200 | 02/2016
47
Deviations in measured values
NOTICE
For the double-rotor brake, the second rotor is included with the "complete flange" compo-
nent. This component must be completely replaced as needed; it should not be taken apart!
Measured value
Cause
Remedy
Voltage too high
Brake voltage does not
match the rectifier
Adjust rectifier and brake voltage to each other.
Voltage too low
Brake voltage does not
match the rectifier
Adjust rectifier and brake voltage to each other.
Defective rectifier diode
Replace defective rectifier with a suitable
undamaged one.
AC voltage is not mains
voltage
Fuse is missing or defec-
tive
Install fuse.
Exchange fuse.
Tab. 20:
Deviations in measured values