Technical specifications
INTORQ | BA 14.0200 | 02/2016
16
3.4
Rated data (dimensioning data) electrical data
3.5
Switching times
Engagement time
The transition from a brake-torque-free state to a holding-braking torque is not free of time lags.
❚
The engagement times apply for
DC switching
with a spark suppressor.
-
Spark suppressors are available for the rated voltages.
-
Connect the spark suppressors in parallel to the contact. If this switching is not admissible for safety
reasons (e.g. with hoists and lifts), the spark suppressor can also be connected in parallel to the
brake coil.
-
Circuit proposals:
❚
The engagement times are approx. 10 times longer with
AC switching
.
-
Connection:
Type
Voltage Power
Coil
resistance
Current
Release
±10%
(1.3 sec.)
Holding
±10%
Brake
release
Holding
Brake
release
Holding
U
L
[V DC]
U
H
[V DC]
P
L
[W]
P
H
[W]
R
N
± 5% [
]
I
L
[A]
I
H
[A]
BFK471-25
205
103
440
110
96.5
2.14
1.07
360
180
294.6
1.22
0.61
Tab. 5:
Coil powers of the BFK471-25
Type
BFK471-25
Rated torque M
dyn
at 100 rpm
Reduction of rated torque M
dyn
to X [%]
Design
[Nm]
1500 rpm
1800 rpm
with one rotor
750
70 %
65 %
double rotor
1500
Tab. 6:
Rated torque reduction depending on the speed of rotation