Electrical installation
INTORQ | BA 14.0200 | 02/2016
29
Tab. 11:
Connection voltages / coil voltages
The brake requires voltage switching. The rated voltage of the brake corresponds to the release voltage
U
N
= U
L
.
5.4
Electrical connection
5.4.1
Switching suggestions
AC switching, delayed engagement
Fig. 14
Bridge-half-wave rectifier in parallel to the motor, extremely delayed engagement
Rectifier type
Supply voltage
Coil voltage
U
L
release /U
H
holding
[V AC]
[V DC]
BEG-561-255-130
230
±10%
205 / 103
BEG-561-440-130
400
±10%
360 / 180
NOTICE
If the rectifier is connected to the neutral point of the motor, the neutral conductor must
also
be connected to this point. Otherwise, the rectifier and the brake may be damaged if there is a
mains phase loss.