Electrical installation
INTORQ | BA 14.0199 | 08/2016
31
5.4
Minimum bend radius for the brake connection line
5.5
Bridge/half-wave rectifier (optional)
BEG-561-
-
The bridge-half-wave rectifiers are used to supply electromagnetic DC spring-applied brakes which are ap-
proved for the use with such rectifiers. Other use is only permitted with the approval of INTORQ.
Once a set over-excitation time has elapsed, the bridge-half-wave rectifiers switch over from bridge rectifi-
cation to half-wave rectification.
Terminals 3 and 4 are located in the DC circuit of the brake. The induction voltage peak for DC switching
(see "DC switching - fast engagement" circuit diagram) is limited by an integrated overvoltage protection at
terminals 5 and 6.
5.5.1
Assignment: Bridge/half-wave rectifier – brake size
Brake size
Wire cross-section
Minimum bendradius [mm]
06
AWG 20
28
08
10
12
14
16
AWG 16
46
18
Tab. 9:
Minimum bend radius for the brake connection line
Rectifier type
Supply voltage
Over-excitation
Holding current reduction
Coil voltage
Size
Coil voltage
Size
[V AC]
[V DC]
[V DC]
BEG-561-255-030
230
103
06 – 18
205
06 – 12
BEG-561-255-130
–
14 – 18
BEG-561-440-030-1
400
180
06 – 18
–
–