Commissioning and operation
INTORQ | BA 14.0214 | 10/2019
46
7.3
During operation
DANGER
Danger: rotating parts!
The running rotor must not be touched.
DANGER
There is a risk of injury by electrical shock!
The live connections must not be touched.
¾
Checks must be carried out regularly. Pay special attention to:
– unusual noises or temperatures
– loose fixing elements
– the condition of the electrical cables
¾
The armature plate must be tightened and the rotor must move without residual torque.
¾
Measure the DC voltage at the brake.
– After the over-excitation time (refer to the table ), the measured DC voltage must correspond to the
holding voltage (refer to Assignment: Bridge/half-wave rectifier – brake size). A deviation of ±10 %
is permissible.
¾
If a fault occurs once, go through the troubleshooting table (siehe the chapter Troubleshooting and
fault elimination). If the fault cannot be fixed or eliminated, please contact the customer service depart-
ment.