Electrical installation
INTORQ | BA 14.0214 | 10/2019
37
6
Electrical installation
Important notes
DANGER
There is a risk of injury by electrical shock!
¾
The electrical connections may only be made by trained electricians!
¾
Make sure that you switch off the electricity before working on the connections! There
is a risk of unintended start-ups or electric shock.
NOTICE
Make sure that the supply voltage matches the voltage specification on the name plate.
NOTICE
¾
If an emergency stop is carried out without the required suppressor circuit, the control
unit may be destroyed.
¾
Observe the correct polarity of the suppressor circuit!
NOTICE
¾
To functionally test the individual brake circuits, the power supply must be able to be
switched off individually. For a new over-energizing during switch-on, it is also neces-
sary to open switches K1/K3.
¾
The protective circuitry contained in the INTORQ switching device BEG-561- □□□-
□□□ is not permitted for use in the lift technology. The protective circuitry must be
connected in parallel to the brake coil (refer to the figure ).