Electrical installation
INTORQ | BA 14.0215 | 07/2019
39
6.2
Bridge/half-wave rectifier (optional)
BEG-561-
□□□
-
□□□
The bridge-half-wave rectifiers are used to supply electromagnetic DC spring-applied brakes which are ap-
proved for use with such rectifiers. Other use is only permitted with the approval of INTORQ.
Once a set overexcitation period has elapsed, the bridge-half-wave rectifiers switch over from bridge recti-
fication to half-wave rectification.
Terminals 3 and 4 are in the DC circuit of the brake. The induction voltage peak for DC switching (refer to
the circuit diagram DC switching at the motor – fast engagement) is limited by an integrated overvoltage
protection at terminals 5 and 6.
6.2.1
Assignment: Bridge/half-wave rectifier – brake size
Rectifier type
Connection voltage
Coil voltage
Release / holding
Assigned brake
[V AC]
[V DC]
BEG-561-255-130
230
±10%
205 / 103
BFK455-25 (205 V)
BEG-561-440-130
400
±10%
360 / 180
BFK455-25 (360 V)
Fig. 23:
BEG-561 fastening options