195A
SAVE THESE INSTRUCTIONS
(195IO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 07/17/2013
English
Page 14
OPERATING INSTRUCTIONS
Valve Position
Function
Water Flow Direction
FILTER
(see drawing 23)
Normal filtration and regular vacuuming
of pool
From pump through filter media to
pool
BACKWASH
(see drawing 24)
Reverses water flow to clean filter
media
From pump through filter media to
valve waste/drain outlet
RINSE
(see drawing 25)
For initial startup cleaning of the sand, and
leveling the sand bed after backwashing
From pump through filter media to
valve waste/drain outlet
WASTE
(see drawing 26)
For vacuuming directly to waste,
lowering pool level or to drain the pool
From pump to valve waste/drain
outlet bypassing the filter media
RECIRCULATE
(see drawing 27)
For circulating water back to pool
without going through the filter media
From pump through valve to pool
bypassing the filter media
CLOSED
(see drawing 28)
Shuts off all flow to filter and pool
“Do not use this setting with pump running”
6-way valve positions and function:
• Risk of electric shock. Connect this product only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI) or
residual current device (RCD). Contact a qualified electrician if you
cannot verify that the receptacle is protected by a GFCI/RCD. Use a
qualified electrician to install the GFCI/RCD, which has a maximum rate
of 30mA. Do not use a portable residual current device (PRCD).
•
To reduce the risk of electric shock, do not use extension cords, timers,
plug adaptors or converter plugs to connect unit to electric supply;
provide a properly located outlet.
•
Do not attempt to plug in or unplug this product while standing in water
or when your hands are wet.
• Never operate this product above the maximum working pressure stated
on the filter tank.
• Always switch off pump before changing the 6-way valve position.
• Operating this product without water flowing through the system can
cause a build up of hazardous pressure which can result in an explosive
situation, serious injury, property damage or death.
• Never test this pump with compressed air. Never operate the system
with water temperature above 35° C (95° F).
WARNING
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
E
S
O
L
C
E
T
S
A
W
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
T
S
A
W
R
E T L I
F
E S
N I R
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
R
E T L I
F
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
B
23
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
E
S
O
L
C
E
T
S
A
W
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
T
S
A
W
R
E T L I
F
E S
N I R
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
R
E T L I
F
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
B
24
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
E
S
O
L
C
E
T
S
A
W
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
T
S
A
W
R
E T L I
F
E S
N I R
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
R
E T L I
F
E S
N I R
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
R
E T L I
F
E
T
AL
U
C
RI
C
E
R
H
S
A
W
K
C
A
B
E
S
O
L
C
E
T
S
A
W
B
25