background image

352

PO

S  AVE THESE INSTRUCTIONS

(352PO)  SPA  ENGLISH  7.5” X 10.3”  PANTONE 295U  12/16/2021

English

Page 14

SPA CONTROL PANEL

OPERATION (continued)

Heat Button: 

Press this button to activate the heating system. Press   or   to set the desired water 

temperature. The heater will continuously heat until the water temperature reaches the set temperature 

and then hold at that temperature. This is achieved by the heater restarting automatically whenever 

the water temperature drops 1.8-3.6°F (1-2°C) below the set temperature. When the fl ame icon on the 

display is red, the heating system is activated. When the fl ame icon turns green, the water is at the set 

temperature. The heating system is then at rest, but the fi ltration system will continue circulating water 

nonstop, unless manually turned off . If the heating system is reactivated, the fi lter pump will restart at the 

same time.

NOTE:

 To stop the fi ltration system while the heater is at rest mode, press the fl ame button fi rst and then 

the fi lter button. Pressing the heat button only while the heater is at rest mode will turn off  the heating 

system only and the fi ltration system will operate for 1 more minute before it turns off  or continue with the 

fi lter pump preset operating hours. To turn the heater off  while heating, press the fl ame button.

IMPORTANT:

 The following conditions will lead to slow water heating.

•  The ambient temperature is lower than 50ºF (10ºC).

•  Outdoor wind speed is above 3.5-5.4 m/s (8-12 mph).

•  The air bubble function is activated when heating the spa water.

•  The spa is not properly covered with the spa cover when the water is heating.

Heater Start Timer (HST) Button: 

Use this button to select a future start time for the heating system. 

Press this button and then press   or   to set the number of hours by which you wish to delay the 

start of the heating system, from 000 to 120 hours. The icon will fl ash red for a few seconds and then 

stays red. The information shown on the LED display alternates between the remaining hours before 

heater start and the water temperature. Once the countdown timer reaches 000, the heating system will 

start operating. To deactivate the function at any time, simply set the HST time back to 000. To readjust 

the preset hours, press the HST button twice and adjust the hours with   and   buttons.

Example 1:

 It is 9:00pm Monday evening and you would like the spa to be hot on Friday evening. 

Allowing for 24 hours for the spa to heat up (4 persons model about 3-4.5ºF (1.5-2.5ºC) per hour) the 

heater should be set to start on Thursday evening. With the Spa turned on, fi rst press the Heat button 

and set your desired temperature. Press the HST button and then   or   until 072 hours is shown. 

The heater will start after 72 hours has passed (Thursday at 9:00pm) and will run until the desired 

temperature is attained. The heater will then cycle on and off  to maintain the set temperature until turned 

off . To turn off  the heater, press the fl ame button.

Heater Duration Timer (HDT) Button:

 Use this button to select the desired length of time the heating 

system should operate. Press this button and then press   or   to set the number of hours you wish 

the heater to operate before it automatically turns off , from 000 to 048 hours. The icon will fl ash red for 

a few seconds and then stays red. The heating system will operate for the amount of preset hours only. 

The timer takes priority over temperature, so the heater will shut off  when HDT time runs out regardless 

if the preset spa water temperature is reached or not. During the HDT function, the information shown 

on the LED display alternates between the remaining heater operating hours and the water temperature. 

Repeat previous steps to reprogram this function. To deactivate the function at any time, simply set the 

HDT time back to 000. To readjust the preset hours, press the HDT button twice and adjust the hours 

with   and   buttons.

Example 2: 

Using the same scenario as example 1 above but rather than manually turning the heater off  

when you are fi nished, you would like the heater to turn off  automatically on Saturday evening at 9:00pm. 

After going through the steps in example 1, press the HDT button and then the   or   button to select 

048 hours. The heater will then run from Thursday at 9:00pm to Saturday at 9:00pm.

NOTE: 

If HST and HDT timers are both set, the LED display will fi rst alternate between remaining time 

before the heater start and the water temperature, until HST timer runs out and the heater activates. 

Then the LED display alternates between remaining HDT time and water temperature until the HDT timer 

runs out as well.

I:  Heat Button 
J:  Heater Start Timer (HST) Button
K:  Heater Duration Timer (HDT) Button

J

I

K

Содержание PureSpa Greywood Deluxe SB-HWF10

Страница 1: ...pearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT SAFETY RULES Please read understand and follow all instructions carefully before...

Страница 2: ...in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipmen...

Страница 3: ...t any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not use the spa when it is raining thundering or lightning A wi...

Страница 4: ...uct while standing in water or when your hands are wet Do not leave the spa empty for extended period of time Do not expose the spa to direct sunlight for extended period of time Provide adequate drai...

Страница 5: ...Page 5 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary...

Страница 6: ...RTRIDGE HOUSING LID 2 11797 11797 15 INLET OUTLET PLUG 3 11739 11739 16 SPA TUB 1 10067 12841 17 SPA COVER 1 11841W 12107W 18 SPA COVER INFLATABLE BLADDER PRE INSTALLED IN SPA COVER 1 11689 12108 19 G...

Страница 7: ...must be setup on a level at and smooth surface that is capable of supporting the maximum load of the lled spa with four adult occupants weight 2500 lbs 1136 kg six adults 3500 lbs 1592 kg Make sure th...

Страница 8: ...arge the control panel battery Once the control panel battery is fully charged you may place the control panel on top of the spa tub wall see drawing 2 1 To remove the control panel from the spa tub l...

Страница 9: ...the air blower in ation outlet Pull out the latch to open the cover insert the hose adaptor 24 and reattach the latch to the hose adaptor to secure it in place see drawing 3 3 Unscrew the air valve c...

Страница 10: ...e the Spa Cover Air Bladder 1 Open the in ation valve and insert the in ation hose 7 into the valve press to in ate until it is rm to the touch but not hard see drawing 8 2 Disconnect the in ation hos...

Страница 11: ...turn 90 degree left to return it to the in ation position 3 Replace the cap back NOTE To de ate the spa tub for storage see STORAGE section For Cover Air Bladder 1 Pull valve cap out and squeeze the v...

Страница 12: ...spa cleaning attachment from the spa outlets before spa usage see drawing 12 Re attach them after usage for water ltration and cleaning 4 Before lling with water ensure the bottom drain valve caps are...

Страница 13: ...ater temperature If you have selected too many hours keep pressing to repeat the cycle Once the operating time is set the LED display will stop ashing after 10 seconds and the lter pump starts working...

Страница 14: ...utton twice and adjust the hours with and buttons Example 1 It is 9 00pm Monday evening and you would like the spa to be hot on Friday evening Allowing for 24 hours for the spa to heat up 4 persons mo...

Страница 15: ...unction on your spa and program a schedule for future use remotely even when not at home from your mobile device System and WiFi Router Requirement The Spa control base hardware communicates over a 2...

Страница 16: ...ith the following status OFFLINE with a red dot at the front WiFi connection failed ONLINE with a green dot at the front mobile device and spa control panel paired up successfully to the same WiFi rou...

Страница 17: ...ched and then hold at that temperature until the 5 hours run time has expired regardless if the water temperature has reached 104 F 40 C or not 40 104 012H 005H Turn the heater on some time into the f...

Страница 18: ...to heat up the water to the desired temperature If problem persists contact Intex Service center E95 Water temperature too high Turn o and unplug the control unit When the water has cooled down plug...

Страница 19: ...spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper wa...

Страница 20: ...ble Result if too high Scale formation cloudy water shorter lter heater runs eye skin irritation high chlorine demand Calcium Hardness CaCO3 refers to the amount of calcium and magnesium dissolved in...

Страница 21: ...odium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriatic acid NOTE After a...

Страница 22: ...ll chemicals with care and wear extra personnel protective equipment including goggle and gloves It is very important not to splash acid onto your skin or clothing or into your eyes Lowering pH Loweri...

Страница 23: ...g out Spa Tub Cleaning If dirt is visible in the water or water becomes cloudy and proper water chemistry does not clear it up change the water and clean the spa tub See Spa Tub Drainage section on ho...

Страница 24: ...un for an hour before folding 5 Fold the spa tub loosely and avoid any sharp corners to prevent damage or leakage to the spa tub liner 6 Prepare additional new cartridges for next time use 7 Store the...

Страница 25: ...r pump is too hot Turn o and unplug the spa Let it cool down and restart all over again If problem persists contact Intex Service Center FILTRATION PUMP NOT WORKING Dirty lter cartridge Filtration inl...

Страница 26: ...let O ring is in place clean and not damaged SPA IS TOO NOISY IN FILTRATION MODE ONLY Control base components not securely attached Control base ground not level and rm Spa lter motor failed Ensure co...

Страница 27: ...nected to the same WiFi router signal Wrong WiFi password Ensure correct WiFi router password See WiFi pairing section The setup spa location is too far from your WiFi router signal coverage range Ens...

Страница 28: ...is setup If you cannot move your spa then you need to move your WiFi router or add a repeater signal booster so that you can receive signals from your WiFi router at your setup spa location Power o th...

Страница 29: ...steps to disassemble it IMPORTANT You must drain out any remaining water inside the piping system of the control base before replacing any parts Tools required One adjustable wrench and one Philip scr...

Страница 30: ...mal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be su...

Отзывы: