manualshive.com logo in svg
background image

352

PO

S  AVE THESE INSTRUCTIONS

(352PO)  SPA  ENGLISH  7.5” X 10.3”  PANTONE 295U  12/16/2021

English

Page 12

SET UP (continued)

Spa Control Unit Installation

1.

  Connect the spa control unit to the spa tub 

(see drawing 10)

. Hand-tighten the connectors securely. 

Do not use tools to tighten.

 

NOTE:

 Never attach external accessories not supplied with the kit to the spa tub or control base unit, 

as this will void the warranty.

2.

  Replace the control base side covers

 (4)

 

(see drawing 11)

.

 

  CAUTION: 

Do not sit, lean, cover or place any objects over the spa control unit.

3.

  Attach the two fi lter cartridge housing assemblies to the two outlet    

grids on the inside of the spa (lower position). Infl ate the spa tub

 

fi rst before installing fi lter pump fi ttings. 

 

ATTENTION!

 In order to comply with the requirements of the 

 

Virginia Grahame Baker Act, suction outlets cannot be covered 

 

while the spa is in use. The Act was intended to address high 

 

suction/volume circulation systems but does not exclude low 

 

volume systems as used on this spa. Accordingly, remove the fi lter   
cartridge assemblies and any other spa cleaning attachment from    
the spa outlets before spa usage 

(see drawing 12)

 

Re-attach them after usage for water fi ltration and cleaning. 

4.

  Before fi lling with water ensure the bottom drain valve caps are 

securely closed on the inside and outside.

5.

  Fill the spa tub with freshwater to a level between MIN and MAX 

marked on the inside of the spa wall. Do not over fi ll the spa. 

 

Never  move the spa tub with water inside and/or with the control base attached to the spa as the spa 
or control base may be damaged. 

 

WARNING: 

Never pour water with a temperature higher than 104°F (40°C) into the spa directly. It 

is recommended to fi ll the spa tub with lukewarm water for quick heating and energy saving.

6.

  Place the spa cover and spa air bladder (pre-installed in spa cover) over the spa tub, and make sure 

the spa cover buckles are locked using the key provided after pulling the buckled straps tight.

 

IMPORTANT:

 Inspect the spa cover regularly for leak, premature wear and tear or deterioration. Never 

 

use a damaged spa cover.

7.

  Ensure that the spa base is plugged into a properly located and sized electrical outlet and press the 

 button to turn on the control panel. Press the 

 button on the control panel to activate the heater, 

see “Spa Control Panel” operation section.

11

10

12

Содержание PureSpa Greywood Deluxe SB-HWF10

Страница 1: ...pearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT SAFETY RULES Please read understand and follow all instructions carefully before...

Страница 2: ...in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipmen...

Страница 3: ...t any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not use the spa when it is raining thundering or lightning A wi...

Страница 4: ...uct while standing in water or when your hands are wet Do not leave the spa empty for extended period of time Do not expose the spa to direct sunlight for extended period of time Provide adequate drai...

Страница 5: ...Page 5 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary...

Страница 6: ...RTRIDGE HOUSING LID 2 11797 11797 15 INLET OUTLET PLUG 3 11739 11739 16 SPA TUB 1 10067 12841 17 SPA COVER 1 11841W 12107W 18 SPA COVER INFLATABLE BLADDER PRE INSTALLED IN SPA COVER 1 11689 12108 19 G...

Страница 7: ...must be setup on a level at and smooth surface that is capable of supporting the maximum load of the lled spa with four adult occupants weight 2500 lbs 1136 kg six adults 3500 lbs 1592 kg Make sure th...

Страница 8: ...arge the control panel battery Once the control panel battery is fully charged you may place the control panel on top of the spa tub wall see drawing 2 1 To remove the control panel from the spa tub l...

Страница 9: ...the air blower in ation outlet Pull out the latch to open the cover insert the hose adaptor 24 and reattach the latch to the hose adaptor to secure it in place see drawing 3 3 Unscrew the air valve c...

Страница 10: ...e the Spa Cover Air Bladder 1 Open the in ation valve and insert the in ation hose 7 into the valve press to in ate until it is rm to the touch but not hard see drawing 8 2 Disconnect the in ation hos...

Страница 11: ...turn 90 degree left to return it to the in ation position 3 Replace the cap back NOTE To de ate the spa tub for storage see STORAGE section For Cover Air Bladder 1 Pull valve cap out and squeeze the v...

Страница 12: ...spa cleaning attachment from the spa outlets before spa usage see drawing 12 Re attach them after usage for water ltration and cleaning 4 Before lling with water ensure the bottom drain valve caps are...

Страница 13: ...ater temperature If you have selected too many hours keep pressing to repeat the cycle Once the operating time is set the LED display will stop ashing after 10 seconds and the lter pump starts working...

Страница 14: ...utton twice and adjust the hours with and buttons Example 1 It is 9 00pm Monday evening and you would like the spa to be hot on Friday evening Allowing for 24 hours for the spa to heat up 4 persons mo...

Страница 15: ...unction on your spa and program a schedule for future use remotely even when not at home from your mobile device System and WiFi Router Requirement The Spa control base hardware communicates over a 2...

Страница 16: ...ith the following status OFFLINE with a red dot at the front WiFi connection failed ONLINE with a green dot at the front mobile device and spa control panel paired up successfully to the same WiFi rou...

Страница 17: ...ched and then hold at that temperature until the 5 hours run time has expired regardless if the water temperature has reached 104 F 40 C or not 40 104 012H 005H Turn the heater on some time into the f...

Страница 18: ...to heat up the water to the desired temperature If problem persists contact Intex Service center E95 Water temperature too high Turn o and unplug the control unit When the water has cooled down plug...

Страница 19: ...spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper wa...

Страница 20: ...ble Result if too high Scale formation cloudy water shorter lter heater runs eye skin irritation high chlorine demand Calcium Hardness CaCO3 refers to the amount of calcium and magnesium dissolved in...

Страница 21: ...odium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriatic acid NOTE After a...

Страница 22: ...ll chemicals with care and wear extra personnel protective equipment including goggle and gloves It is very important not to splash acid onto your skin or clothing or into your eyes Lowering pH Loweri...

Страница 23: ...g out Spa Tub Cleaning If dirt is visible in the water or water becomes cloudy and proper water chemistry does not clear it up change the water and clean the spa tub See Spa Tub Drainage section on ho...

Страница 24: ...un for an hour before folding 5 Fold the spa tub loosely and avoid any sharp corners to prevent damage or leakage to the spa tub liner 6 Prepare additional new cartridges for next time use 7 Store the...

Страница 25: ...r pump is too hot Turn o and unplug the spa Let it cool down and restart all over again If problem persists contact Intex Service Center FILTRATION PUMP NOT WORKING Dirty lter cartridge Filtration inl...

Страница 26: ...let O ring is in place clean and not damaged SPA IS TOO NOISY IN FILTRATION MODE ONLY Control base components not securely attached Control base ground not level and rm Spa lter motor failed Ensure co...

Страница 27: ...nected to the same WiFi router signal Wrong WiFi password Ensure correct WiFi router password See WiFi pairing section The setup spa location is too far from your WiFi router signal coverage range Ens...

Страница 28: ...is setup If you cannot move your spa then you need to move your WiFi router or add a repeater signal booster so that you can receive signals from your WiFi router at your setup spa location Power o th...

Страница 29: ...steps to disassemble it IMPORTANT You must drain out any remaining water inside the piping system of the control base before replacing any parts Tools required One adjustable wrench and one Philip scr...

Страница 30: ...mal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be su...

Отзывы: