background image

(328PO)  MODEL ZS6110  OZONE & SALTWATER SYSTEM  ENGLISH  7.5” X 10.3”  PANTONE 295U  01/22/2021

328

PO

    

SAVE THESE INSTRUCTIONS

English

Page 6

SETUP INSTRUCTIONS

1.

  Assemble the above-ground-pool (AGP) and its filter pump according to their installation 

 

instructions.

2.

  Take the Ozone & Saltwater System and its accessories out of the packaging.

3.

  Place the Ozone & Saltwater System in line after the filter pump.

4.

  Connect the connector hose 

(8)

 to the Ozone & Saltwater System inlet.

Connecting the system to pump and pool with 1-1/2” (38mm) connections/hoses, 
install as follows:

Drawing #1

IMPORTANT

•  The Ozone & Saltwater System requires a separate filter pump [1600~4000 gph 
  (6056~15140 lph)] to drive the water and function properly.
•  The Ozone & Saltwater System must be installed as the last piece of pool equipment 
  in the water return line to the pool as displayed in Drawing #1. This location extends 
  the life of the titanium plates.

1.

  Go directly to step 2 if your pool is empty. If your above-ground-pool is filled with water, close 

 

the plunger valves before installing the Ozone & Saltwater System.

2.

  Disconnect the water return hose from the filter pump connection and connect it to the Ozone

 

& Saltwater System outlet.

3.

  Connect the connector hose 

(8)

 to the filter pump outlet connection.

4.

  Open the plunger valves to allow the water to flow.

 

 

 

 

FILTER

PUMP

ID 1-1/2” (38mm) 

HOSE

ID 1-1/2” (38mm) 

HOSE

OZONE & 

SALTWATER 

SYSTEM

SWIMMING POOL

WATER TO 

POOL

PLUNGER 

VALVE

WATER 

FROM POOL

8

Содержание Krystal Clear ZS6110

Страница 1: ... Toys Airbeds and Boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT DO NOT RETURN PRODUCT TO STORE To purchase parts and accessories or to obtain non technical assistance...

Страница 2: ...s Salt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating Time Table 12 Operating Instructions 13 14 LED Code Chart 15 Maintenance 16 18 Long Term Storage 18 Pool Maintenance and Chemical Definitions 19 Troubleshooting Guide 20 21 Control Station Replacement 22 General Aquatic...

Страница 3: ...imers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not use an appliance leakage current interrupter ALCI in place of a GFCI since the ALCI will not protect people Position this product away from the pool so as to prevent children from climb...

Страница 4: ...duct may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR 1 10849 2 L SHAPE O RING 2 11228 3 SCREW 2 11519 4 TITANIUM ELECTRODE NUT 1 11432 5 TITANIUM ELECTRODE 1 11374 6 O RING ON TITANIUM PLATES 1 11515 7 FLOW SENSOR 1 11460 8 CONNECTOR HOSE WITH THREADED FITTINGS 1 10720 9 ELECTROLYTIC ...

Страница 5: ...110 120 Volt AC Amperage 1 1A Ideal Salt Level 3000 ppm parts per million Maximum sodium hypochlorite output hour 11 grams hour Ozone Output 150 mg hour Filter pump minimum flow rate 1600 4000 gallons hour 6056 15140 liters hour Limited Warranty see Limited Warranty Flow Sensor Electrolytic Cell Control Station Hose from Filter Pump Hose Returning Water to Pool ...

Страница 6: ...te filter pump 1600 4000 gph 6056 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the pool as displayed in Drawing 1 This location extends the life of the titanium plates 1 Go directly to step 2 if your pool is empty If your above ground pool is filled with water close the plunger valves...

Страница 7: ...arge hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This is depicted in Drawings 1 Following are the common connection types Connection to 1 1 2 38mm connectors without thread 1 Connect the adaptor A 1 to the Ozone Saltwater System outlet Tighten securely 2 With the adaptor A 1 fixed to...

Страница 8: ...ded The salt in the pool is constantly recycled Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater System turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly spread the proper amount of salt around the inside perimeter of the pool 5 Avoid clogging the filter Do not add salt through the skimmer 6 Brush the pool bottom to speed...

Страница 9: ... 45 25 10 15 x 48 457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24 x 52 732cm x 132cm 12481 47241 310 140 80 35 ULTRA FRAME POOL 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 18 x 52 549cm x 132cm 6981 26423 175 80 45 20 20...

Страница 10: ... 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 GRAPHITE GRAY PANEL POOL SET 15 8 x 49 478cm x 124cm 4440 16805 1 1 0 5 16 8 x 49 508cm x 124cm 5061 19156 1 3 0 6 18 8 x 53 569cm x 135cm 6981 26423 1 7 0 8 OVAL FRAME POOL 18 x 10 x 42 549cm x 305cm x 107cm 2885 10920 0 7 0 3 20 x 12 x 48 610cm x...

Страница 11: ... 2 2 3 4 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 21 x 52 640cm x 132cm 9533 36082 4 5 6 8 24 x 52 732cm x 132cm 12481 47241 5 6 7 8 ULTRA FRAME POOL 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 18 x 52 549cm x 132cm 6981 26423 3 4 5 6 20 x 48 610cm x 122cm 7947 30079 4 4 5 6 22 x 52 671cm x 132cm 10472 39637 5 5 6 8 24 ...

Страница 12: ...tup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 Water Capacity Operating Time hours at different ambient air temperatures Gals Liters 10 19 C 50 66 F 20 28 C 68 82 F 29 36 C 84 97 F 2000 4000 6000 8000 10000 12000 14000 7500 15000 22500 30000 3...

Страница 13: ...will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating Make sure to program your filter pump or start it manually for operation beginning 5 minutes before the Ozone Saltwater System and finishing 15 minutes after the Ozone Saltwater System 4 Lock keypad control...

Страница 14: ...n the control panel lights up and the LED display flashes 93 The system is now in Stand By mode After a while it shuts down and sets itself in a Power Saving mode The system will automatically turn itself back on in 24 hours starting its daily cycle of sodium hypochlorite production The SLEEP indicator stays on while the system is in the Power Saving mode The LED display however goes blank after 5...

Страница 15: ...ning 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code Low Pump Flow No Pump Flow 91 Alarm Code Low Salt Level 92 Alarm Code High Salt Level 93 Stand By Mode Operating Process finished BLANK No Power or Power Saving Mode waiting to start ne...

Страница 16: ...its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases this self cleaning action will keep the cell working at optimum efficiency If the pool water is hard high mineral content the cell may require periodic manual cleaning To maintain maximum performance we recommend that you...

Страница 17: ...he flow sensor from the electrolytic cell 9 housing 5 Pour kitchen grade vinegar into the electrolytic cell 9 to immerse the titanium electrodes Soak for 1 hour 6 Open one side of the cell cover 11 drain and properly dispose of the vinegar Connect the hose which goes from the pool to the cell Flush the electrolytic cell housing with the pool water 7 Reverse steps 3 4 5 and 6 to reconnect the elect...

Страница 18: ...st the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hoses by reversing the installation instructions 3 Air dry the unit before ...

Страница 19: ...ed to the water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result if too high Scale will form and will cause the water to become cloudy Stabilizer Stabilizers extend the life of chlorine in swimming pools Cyanuric Acid Do not add pool che...

Страница 20: ... turn on Reset the RCD GFCI Contact Intex Service Center PROBLEM CAUSE SOLUTION IMPORTANT If you continue to experience difficulty please contact our Consumer Service Department for assistance See separate Authorized Service Centers sheet This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 th...

Страница 21: ...the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor receptacle Reset both timers on the filter pump and Ozone Saltwater System Contact Intex Service Center Remove the electrolytic cell for inspect...

Страница 22: ... is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruct all pool users including children what to do in case of an emergency Always use common sense and good judgement when enjoying any water activity Supervise supervise supervise For additional information on safety please visit The Association of Pool and Spa Prof...

Страница 23: ... be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal...