(328PO) MODEL ZS6110 OZONE & SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
328
PO
SAVE THESE INSTRUCTIONS
English
Page 21
TROUBLESHOOTING GUIDE (continued)
1
. Filter pump not attached to system
and/or switch on.
2
. Circulation line is blocked.
3
. Incorrect inlet and outlet hose direction.
4
. Scale on the flow sensor.
5
. Flow sensor cord is loose.
6
. Inner timer conflict between filter pump
and Ozone & Saltwater system.
7
. Flow sensor failure.
1
. Dirt or scale on titanium plates.
2
. Low salt level / No salt.
3
. Electrolytic cell cord is loose.
4
. Possible electrolytic cell failure.
1
. High salt level.
2
. Water temperature > 35ºC.
3
. Titanium electrode failure.
1
. LED display is off and the “SERVICE”
light is on - the system does not power
up.
2
. Caused by high humidity.
3
. PCB failure.
1
. Ozone generator assembly failure.
• Ensure filter pump is attached and operating.
See "Setup Instruction".
• If your unit has plunger valves, ensure that
they are open.
• Clear your filter cartridge and cell from debris
and dirt. See “Maintenance”.
• Release all trapped air in the circulation line.
See the filter pump manual.
• Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See
“Set Up Instructions”.
• Clean the flow sensor, paying special attention
to the hinge. See “Maintenance”.
• Plug the flow sensor firmly into the flow sensor receptacle.
• Reset both timers on the filter pump and
Ozone & Saltwater System.
• Contact Intex Service Center.
• Remove the electrolytic cell for inspection.
Clean it if necessary. See “Maintenance”.
• Add salt. See “Salt & Pool Water Volumes”.
• Ensure that the cell cord is plugged firmly into
the cell housing receptacle.
• Contact Intex Service Center. Replace the cell if needed.
• Partially drain the pool and refill it with fresh
water. See “Salt & Pool Water Volumes”.
• Contact Intex Service Center
.
• Household voltage is too high or too low (+ 20%).
Check the voltage is within the range stated on the
device housing.
• Run the system during midday and avoid running it
during dawn, foggy or raining time. Place a piece of
tile or similar pad, 15”x15” (38x38 cm) in size,
between the device and the ground to keep ground
water evaporation away from the system.
• Contact Intex Service Center.
• Contact Intex Service Center.
LED PANEL
CODE
PROBLEM
SOLUTION
LED Panel Code Flash & Alarm On (
NOTE:
Always turn off the power before cleaning and servicing).