background image

341

PO

SAVE THESE INSTRUCTIONS

(341PO)  MODEL SF90110-1 SAND FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  

04/01/2021

English

Page 21

TROUBLESHOOTING GUIDE

TROUBLE

 CAUSE

SOLUTION

• Line cord must be plugged into a 3 wire outlet

that is protected by a Class A Ground Fault
Circuit Interrupter, or RCD.

• Reset circuit breaker. If circuit breaker trips

repeatedly, your electrical system may have a
defect. Turn off circuit breaker and call an
electrician to correct the problem.

• Let the motor cool down and restart again.

• Adjust the chlorine and pH level. Consult your

local swimming pool supply stores.

• Load with filter sand, see “sand loading

instructions”.

• Set valve to “FILTER” position.
• Operate the filter for longer periods.
• Clean the strainer screen at the inlet.

• Release the air, see operating instructions section.
• Clear any obstructions in the intake hose by

discharging it inside pool wall.

• Tighten hose nuts, check hoses for damage,

check pool water level.

• Backwash filter.
• Install the nozzle at the upper position of the

pool inlet, and the strainer at the lower
position of the pool outlet.

• Remove about 1” of sand if necessary.
• Remove any pool vacuuming device attached

to the system line.

• Make sure the inlet threaded air connector is

connected to the pool inlet upper hole.

• Fill pool to correct water level.
• Clean strainer screens at pool inlet.
• Tighten hose nuts, check hose for damage.
• Contact Intex service center.

• Remove 6-way valve cover and ensure the

o-ring is in place.

• Clean sand tank o-ring with garden hose water.
• Tighten securely.
• Contact Intex service center.

• Tighten/reinstall hose nut.
• Ensure o-ring/L-shape o-ring is in place and

not 

damaged.

• Turn off the pump and restart 5 minutes later.
• Re-set the timer.
• Contact Intex service center.

• Clear any obstructions in the intake by

unscrewing it from the 6-way valve.

• Contact Intex service center.

• Use only No. 20 silica sand with particle size

range 0.45 to 0.85 mm (0.018 to 0.033 inches)
and a Uniformity Coefficient less than 1.75.

• Change sand.

• Tighten or reinstall plunger valve.
• Tighten air jet valve and make sure it’s

facing 

up.

• Turn pump ON and run for few seconds, then

turn OFF, repeat 3 times.

• Remove air jet valve, flush dirt out with water

and replace valve back.

• Replace a new air jet valve.

FILTER MOTOR 
FAILS TO START

FILTER DOESN’T 
CLEAN POOL

FILTER DOESN’T 
PUMP WATER OR 
FLOW IS VERY 
SLOW

PUMP DOESN’T 
WORK

6-WAY VALVE/
COVER LEAKING

HOSE LEAKING

TIMER IS 
INACCURATE OR 
TIMER CAN'T BE SET 

PRESSURE GAUGE  
DOESN’T WORK

SAND IS FLOWING 
BACK INTO THE 
POOL

INLET TREADED
AIR CONNECTOR 
/ AIR JET VALVE 
LEAKING

• The motor is not plugged in.
• The GFCI/RCD circuit breaker is

tripped.

• Motor too hot and overload

protection is shut off.

• Improper chlorine or pH levels.
• No filtering media in tank.
• Wrong 6-way valve setting

position.

• Excessively dirty pool.
• The strainer screen is restricting

the water flow.

• Trapped air in the system.
• Clogged inlet or discharge.
• An air leak on the intake line.
• Excessively dirty pool.
• Sand media clogged with dirt.
• Nozzle and strainer connections

are 

reversed.

• Crusting or caking on the filtering

sand 

surface.

• Pool vacuuming device attached

to the system.

• Inlet threaded air connector

connected to the wrong hole on
the 

liner.

• Low water level.
• Strainer screen clogged up.
• An air leak on the intake hose.
• Faulty motor or the impeller is jammed.

• Sand tank o-ring missing.
• Sand tank o-ring dirty.
• Flange clamp not tight.
• 6-way valve damage.

• Hose nut not securely tight.
• Hose connection fitting

o-ring/L-shape o-ring missing.

• Possible inner timer defective.

• Clogged inlet of the pressure

gauge.

• Pressure gauge damage.

• Sand is too small.
• Sand bed is calcified.

• Plunger valve not well-fitted.
• Air jet valve is not tight and

facing 

 

up.

• Air jet valve internal seal blocked.
• Air jet valve internal seal dirty.
• Air jet valve broken.

Содержание Krystal Clear SF90110-1

Страница 1: ...Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction manual without notice OWNER S MANUAL...

Страница 2: ...nings 3 Parts References 4 6 Setup Instructions 7 14 Product Specifications 9 Operating Instructions 15 17 Intex Pools Operating Time Table 18 Non Intex Pools Operating Time Table 19 Maintenance 20 Lo...

Страница 3: ...when your hands are wet Do not use an appliance leakage current interrupter ALCI in place of a GFCI since the ALCI will protect people Position this product away from pool so as to prevent children fr...

Страница 4: ...U 04 01 2021 English Page 4 PARTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose...

Страница 5: ...for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment...

Страница 6: ...22 HOSE O RING 2 10262 23 STEP WASHER 2 10745 24 STRAINER NUT 2 10256 25 FLAT STRAINER RUBBER WASHER 2 10255 26 THREADED STRAINER CONNECTOR 1 10744 27 ADJUSTABLE POOL INLET JET NOZZLE 1 12369 28 ADAPT...

Страница 7: ...er 25 on the connector 26 3 Install the strainer and plunger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 26 into one of the pre cut holes w...

Страница 8: ...acing the outside wall of the liner in a clockwise motion screw the strainer nut 24 back onto the inlet threaded air connector 38 see drawing 6 5 Finger tighten the adjustable pool inlet jet nozzle 27...

Страница 9: ...not install the pump in a damp or non ventilated location A team of 2 or more people is recommended for setting up this product Leaf trap setup 1 Make sure the pump o ring 6 is in place In a clockwis...

Страница 10: ...ide the tank 1 To prevent sand from falling into the center pipe top opening when pouring the sand cover the center pipe top opening with a cup or similar object see drawing 12 2 With one person holdi...

Страница 11: ...tank groove and the 6 way valve cover edge IMPORTANT Ensure the 6 way valve cover ridge is aligned with the groove on the tank rim WARNING Improper tank valve and clamp assembly could cause the valve...

Страница 12: ...to be secured to the ground or to a base in a permanent upright position Check your local authorities to determine if there is a regulation in your area regarding above the ground swimming pool filte...

Страница 13: ...ve the drain cap before attaching the drain waste hose or pipe 4 The sand filter pump is now ready to filter the pool WARNING Position this product away from the pool so as to prevent children from cl...

Страница 14: ...ON SETUP continued For INTEX pool with 1 1 4 32mm connections hoses Make sure the air jet valve 37 is securely tighten onto the pool inlet air adaptor 39 and facing up For NON INTEX pool Connect the h...

Страница 15: ...Never test this pump with compressed air Never operate the system with water temperature above 35 C 95 F Valve Position Function Water Flow Direction FILTER see drawing 23 Normal filtration and regula...

Страница 16: ...clear flow of water is observed in the waste drain outlet NOTE If the LED display flashes 00 the device is in stand by mode and the pump will not operate The initial backwash of the filter is recommen...

Страница 17: ...the system will automatically lock it and start working 10 seconds later The sand filter pump is now filtering the water and will stop after the operating hours are completed 4 Readjust operating time...

Страница 18: ...16173 5 18 x 42 549cm x 107cm 4786 18115 5 18 x 48 549cm x 122cm 5455 20647 6 18 x 52 549cm x 132cm 5894 22309 6 ROUND METAL FRAME POOL 12 x 36 366cm x 91cm 2086 7896 2 15 x 36 457cm x 91cm 3282 12422...

Страница 19: ...age 19 NON INTEX POOLS OPERATING TIME TABLE This table shows the required operating time for average use of the sand filter pump with above ground pools Water Capacity Sand filter pump operating time...

Страница 20: ...should be controlled between 0 degrees Celsius 32 degrees Fahrenheit and 40 degrees Celsius 104 degrees Fahrenheit POOL CARE CHEMICALS All pools require care to keep the water clear and hygienically c...

Страница 21: ...it from the 6 way valve Contact Intex service center Use only No 20 silica sand with particle size range 0 45 to 0 85 mm 0 018 to 0 033 inches and a Uniformity Coefficient less than 1 75 Change sand T...

Страница 22: ...orinate with shock treatment Correct pH to your pool store s recommended level Vacuum pool bottom Maintain proper chlorine level Adjust pH level to the recommended level Run filter until water is clea...

Страница 23: ...inted as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about pot...

Страница 24: ...Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried...

Отзывы: