Power: 

110-120 Volt AC

Amperage: 

3 A

Maximum working pressure: 

3.5 bar (50 psi)

Effective filtering area: 

0.1 m

2

 (1.1 ft

2

)

Maximum Flow Rate: 

6056 liters/hour (1600 gallons/hour)

Recommended filtering media: 

No. 20 silica sand or glass sand. Particle size 

(Not included)  

range 0.45 to 0.85 mm (0.018 to 0.033 inches). 

   

Uniformity Coefficient less than 1.75.

Recommended filtering media quantity:  No. 20 silica sand 25 Kg (55 Lbs) or glass sand

  

18 Kg (40 Lbs).

Limited Warranty: 

see “Limited Warranty”

NOTE: 

NOT SUITABLE FOR USE WITH KCP-LOW -SALT AUTOMATIC SALTWATER 

SYSTEM (MODEL 6110/6220)

The sand filter removes suspended particles but does not sanitize your pool. 

Pool chemistry is a specialized area and you should consult your local pool 

service specialist for details.

TOOLS REQUIRED: One (1) Phillips screwdriver

Pump location and mounting:

•  The system must be installed on a solid level and vibration-free base.

•  Provide a location protected from the weather, moisture, flooding and    

  freezing temperature.

•  Provide adequate access, space and lighting for routine maintenance.

•  Pump motor requires free circulation of air for cooling. Do not install    

  the pump in a damp or non-ventilated location.

A team of 2 or more people is recommended for setting up this product.

Motor pre-filtering assembly setup:

1. 

Remove the sand filter and its accessories   

    from the packaging carefully and inspect for  

    any visible damage. If parts are damaged    

    contact your local service center listed at    

    the back of this owner’s manual.

2. 

In a counter-clockwise motion unscrew the   

    leaf trap cover 

(14) 

from the pre-filter 

    housing. Take out the basket 

(16) 

and filter   

    housing nut 

(17) (see drawing 10)

3.

  Connect the pre-filter housing to the motor    

    water inlet. Note: Align the connector in the   

    pre-filter housing with the water inlet on the   

   motor 

(see drawing 11)

.

10

11

35

17

16

14

Содержание Krystal Clear SF15110

Страница 1: ...right to change specifications and appearance which may result in updates to the instruction manual without notice OWNER S MANUAL For illustrative purposes only IMPORTANT DO NOT RETURN PRODUCT TO STO...

Страница 2: ...ONTENTS Warnings 3 Parts List References 4 8 Setup Instructions 9 16 Product Specifications 11 Operating Instructions 17 19 Intex Pools Operating Time Table 20 Non Intex Pools Operating Time Table 21...

Страница 3: ...unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not use an appliance leakage current i...

Страница 4: ...MODEL SF15110 SAND FILTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 06 26 2012 PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale English PARTS LIST 7 1 9 4 5 2 6 3...

Страница 5: ...AND FILTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 06 26 2012 English PARTS LIST continued PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale 23 25 22 24 26 27 28...

Страница 6: ...tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...

Страница 7: ...TS REFERENCE PARTS REFERENCE continued Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only...

Страница 8: ...D FILTER INTERCONNECTING HOSE 1 11388 14 LEAF TRAP NUT 1 11479 15 LEAF TRAP O RING 1 11232 16 BASKET 1 11260 17 FILTER HOUSING NUT 1 11261 18 L SHAPE O RING 1 11412 19 SEDIMENT RELEASE VALVE 1 10460 2...

Страница 9: ...m the inside of the pool liner insert the connector 26 into one of the pre cut holes with the washer remaining on the connector to be placed against the inside of the liner wall 4 Before assembly lubr...

Страница 10: ...iner nut 24 facing the outside wall of the liner in a clockwise motion screw the strainer nut 24 back onto the threaded connector 26 see drawing 6 5 Finger tighten the adjustable pool inlet nozzle 27...

Страница 11: ...local pool service specialist for details TOOLS REQUIRED One 1 Phillips screwdriver Pump location and mounting The system must be installed on a solid level and vibration free base Provide a location...

Страница 12: ...ing 14 2 NOTE Ensure the pre filter housing water inlet hose connection is facing towards the pool IMPORTANT Some countries especially in the European community require the product to be secured to th...

Страница 13: ...top of the center pipe Pour the sand into the tank at a slow rate see drawing 15 2 Fill the tank approximately half way remove the sand shield 6 from the top see drawing 16 3 Evenly distribute the san...

Страница 14: ...o valve is aligned with the motor outlet see drawing 20 SETUP INSTRUCTIONS SETUP INSTRUCTIONS continued WARNING Improper tank valve and clamp assembly could cause the valve and clamp to blow off and c...

Страница 15: ...inlet nozzle Ensure the hose nuts are securely tighten 3 The third hose connection port drain waste outlet on the 6 way valve shall be directed to a proper draining receptacle using a hose or pipe no...

Страница 16: ...is in place Connect adaptor B 28 to plunger valve union 3 Remove wall plug and then insert the strainer 29 31 into the lower position of protruding hose connection and the nozzle 29 30 into the upper...

Страница 17: ...and regular vacuuming of pool From pump through filter media to pool BACKWASH see drawing 24 Reverses water flow to clean filter media From pump through filter media to valve waste drain outlet RINSE...

Страница 18: ...Ensure the pump is off depress the 6 way valve and turn it to the BACKWASH position see drawings 24 29 IMPORTANT To prevent damage to the 6 way valve always depress the valve handle before turning Alw...

Страница 19: ...cuuming device attached to the system and the pressure gauge reading is in the yellow zone it is time to backwash the sand media see BACKWASH under initial startup and operation section Vacuuming devi...

Страница 20: ...52 12481 47241 8 ULTRA FRAME POOL 488cmx122cm 16 x48 5061 19156 4 549cmx122cm 18 x48 6423 24311 4 549cmx132cm 18 x52 6981 26423 6 610cmx122cm 20 x48 7947 30079 6 671cmx132cm 22 x52 10472 39637 8 732cm...

Страница 21: ...operating time For one cycle Gals Liters Hours 2 4 4 4 4 6 6 6 6 8 8 8 12 12 12 12 12 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 19000 11355 15140 18925 2...

Страница 22: ...opening the sediment release valve 19 located on the lower side of the pre filter housing see drawing 32 4 In a counter clockwise motion unscrew the leaf trap cover 14 then remove the basket 16 and l...

Страница 23: ...Fahrenheit POOL CARE CHEMICALS All pools require care to keep the water clear and hygienically clean With proper chemical control your filter will help attain this objective Consult your pool supply...

Страница 24: ...ter Remove 6 way valve cover and ensure the o ring is in place Clean sand tank o ring with garden hose water Tighten the clamp with wrench supplied Contact Intex service center Tighten reinstall hose...

Страница 25: ...uper chlorinate with shock treatment Correct pH to your pool store s recommended level Vacuum pool bottom Maintain proper chlorine level Adjust pH level to the recommended level Run filter until water...

Страница 26: ...mpetent adult should be appointed as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is supe...

Страница 27: ...Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried...

Отзывы: