POOL MAINTENANCE & CHEMICAL DEFINITIONS
MM
AA
IINN
TT
EE
NN
AA
NN
CC
EE
Free Chlorine
-
Is the chlorine residual present in pool water.
Combined Chlorine
-
Is formed by the reaction of free chlorine with ammonia
wastes.
Result if too high - Sharp chlorinous odor, eye irritation.
pH
-
A value that indicates how acidic or basic a solution is.
Result if too low -
Corroded metals, eye & skin irritation,
destruction of total alkalinity.
Result if too high - Scale formation, cloudy water, shorter
filter runs, eye & skin irritation, poor
chlorine efficiency.
Total Alkalinity
-
Indicates the degree of the water's resistance to change
in pH. It determines the speed and ease of pH change,
so always adjust total alkalinity before adjusting the pH
level.
Result if too low -
Corroded metals, eye & skin irritation.
Low alkalinity will cause the pH to be
unstable. Any chemical added to the
water will have an affect on pH.
Result if too high - Scale formation, cloudy water,
eye & skin irritation, poor chlorine
efficiency.
Calcium Hardness
-
Refers to the amount of calcium and magnesium
dissolved in the water.
Result if too high - Scale will form and will cause the
water to become cloudy.
Stabilizer
-
Stabilizers extend the life of chlorine in swimming pools.
(Cyanuric Acid)
Consult with local swimming pool dealer for water treatment.
• Do not add pool chemicals directly to the skimmer. This may damage the cell.
• Maintaining a salt and sanitizer level above the recommended range can
contribute to the corrosion of the pool equipment.
• Check the expiry date of the test kit as the test results may be inaccurate if the
kit is used after that date.
• If, due to heavy pool usage, it is required to increase the sanitizer level, then use
a chemical based on trichlor, TCCA or dichloro.
Preferred Water Chemistry Reading
Minimum
Ideal
Maximum
Copper Ions
0
0.1 - 0.2 ppm
0.2 ppm
Free Chlorine
0
0.4 - 1.5 ppm
3.0 ppm
Combined Chlorine
0
0 ppm
0.2 ppm
pH
7.2
7.4 - 7.6
7.8
Total Alkalinity
100 ppm
100 - 140 ppm
140 ppm
Calcium Hardness
150 ppm
200 - 400 ppm
500 - 1000 ppm
Stabilizer (Cyanuric Acid)
10 ppm
30 - 50 ppm
100 ppm