EE
ELECTROLYTIC CELL CLEANING
COPPER ELECTRODE CLEANING
If the pool water is hard (high mineral content) the cell may require periodic manual
cleaning. To maintain maximum performance, we recommend that you open and
visually inspect the electrolytic cell
(22)
once every month.
The following steps are some instructions on how to clean your cell.
1
.
Switch off the unit, unplug the power cord from the electrical socket.
2
.
Disconnect the hose
(12)
from the electrolytic cell
(22)
outlet and cover the
outlet with the drain outlet cover
(3)
from the 6-way valve
(see drawings 37
and 38).
3.
Remove the electrolytic cell from the 6-way valve outlet by unscrewing the
electrolytic cell
(22)
collar
(see drawing 39)
.
4.
Pour kitchen grade vinegar into the cell to immerse the titanium plates
(see
drawing 40)
. Soak for about 1 hour and then flush with a high-pressure
garden hose.
5.
Reverse steps 2 to 4 to reconnect the electrolytic cell.
1
.
Switch off the unit, unplug the power cord from the electrical socket.
2
.
In a counter-clockwise motion, unscrew the electrical plug collar from the
copper electrode cell, and remove the electrical plug from electrode cell
(see
drawings 41 and 42)
.
3.
Unscrew the copper electrode cell collar, then remove the electrode cell and
place it on a bucket.
4.
Pour kitchen grade vinegar into the bucket until the copper electrode cell is
immersed
(see drawing 44)
. Soak for 1 hour and then flush with a
high-pressure garden hose.
5.
Reverse steps 2 to 4 to reconnect the copper electrode cell.