6. SERVICE AND MAINTENANCE
The ozone cell (CGC) in the generator must be inspected and if necessary cleaned at least once a year ac-
cording to the instructions below. The air filter must be replaced at least once a year. After the installation
an inspection is recommended after three months.
Always use protective gloves and protective goggles.
Cleaning of the Ozone Cell
1. The power supply must be disconnected from the generator
2. Loosen the four screws that hold the housing and lift it.
3. Carefully clean the glass electrodes and the surfaces on the inside using a soft cloth with cleaning spirit.
Never use sharp tools or abrasives when cleaning the glass electrodes.
NOTE: The glass electrodes are fragile.
4. Reassemble the housing and fasten with the four screws.
5. Connect to power supply.
Replacing the Air Filter
1. Dismount the filter frame by using a screwdriver for the two holes and separate the frame that holds
the filter in place.
2. Remove the old filter and install the new one. Reinstall the filter frame.