Operating Instructions CP VARITHERM DNPA HI

Page 6 / 7

HOM177737483Ien-7

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

1

2

3

4

5

6

7

8

9

10

11

12

13

L
N

PE

NTC

RS 485

F1

TC DIGITAL

CP...THERM...HI

external sensor 

br=brown bl=blue ye/gn=yellow/green bk=black gr=grey

bl  br  gn/ye 

gr  bk 

+

A

B
Ground 

Illustration 3: 

Smart Heater HI System with TC

9

Commissioning

If the heater is installed in accordance with the notes in
the 

Installation  [

}

Page  4]

  section  and 

Connection  [

}

Page  5]

 

sections, 

then 

the 

radiator 

may 

be

commissioned.

 CAUTION

Sufficient heat dissipation must be ensured.

Unauthorized covers must be removed as otherwise
there is the risk of the heater overheating.

The heating circuit is permanently disconnected by a
temperature melt fuse which can't be reset if these
installation instructions are not adhered to.

10

Maintenance

The  design  of  the  device  does  not  require  any
maintenance.

Functional  and  safety  test  intervals  can  be  freely
selected  by  the  operator  in  accordance  with  the
applicable regulations.

Repairs  may  only  be  carried  out  by  the  manufacturer  in
the factory.

All  components  have  to  be  kept  clean  and  free  of  dust
and  harmful  substances  that  could  lead  to  excessive
temperature rise.

11

Troubleshooting

If  the  heater  fails,  check  the  installation.  Carry  out  a
continuity test on the heating circuit. Pay attention to the
connection  diagram  and  switching  point  of  the
thermostat!

In  the  case  of  overheating,  the  thermal  indicator  (see
figure)  indicates  a  discoloration.  If  more  than  four  fields
are  blackened,  the  heater  must  be  uninstalled  and
returned to the manufacturer for inspection.

Illustration 4: 

Temperature indicator

12

Deinstallation

Disassembly  may  only  be  carried  out  by  a  trained
person.

 DANGER

Risk of fatal injury from electric current!

If contact is made with live components, there is the risk
of fatal injury.

For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.

Disconnect connection line from the clamps and from the
connection  socket,  disconnect  device  from  bracket  and
remove it.

13

Disposal

Disassemble  the  components  of  the  product,  taking  the
applicable  local  labour  protection  and  environmental
regulations  into  consideration  and  make  sure  that  the
components are recycled:

• Scrap metal

• Send plastic elements to recycling

• Sort other components according to their material

properties and dispose of them.