Operating Instructions CP VARITHERM DBPA

HOM146742411Ien-6

Page 3 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

1

General

These  operating  instructions  describe  the  safe  and
proper  way  to  work  with  the  device.  The  safety
information  and  instructions  given  as  well  as  the  local
accident  prevention  regulations  and  general  safety
regulations  valid  in  the  area  of  application  must  be
complied  with.  These  instructions  are  a  constituent  part
of  the  instrument  and  need  to  be  kept  in  the  immediate
vicinity of the device accessible to personnel at all times.

Before  starting  any  work,  the  operating  instructions
should be read in full.

2

Use

The CP..THERM heaters are manufactured according to
Directive INMETRO No. 179, of May 18

th

, 2010 and are

licensed  for  direct  heating  through  flange-mounting
(conduction) or for room heating (convection) in Ex-zone
1  and  Zone  2  for  instrument  categories  G/  D  in
temperature  classes  T3  to  T6.  You  will  find  the
temperature  class  for  your  device  on  the  label.  See

Technical Data [

}

Page 4]

 section.

The areas of application are:

• Frost protection

• Condensation protection

• Maintaining temperature

The standard design has a room thermostat integrated in
the connecting cable for frost protection applications or a
safety  thermostat  for  maintaining  temperature.  If  a  TAE
is  used,  the  respective  operating  instructions  must  be
complied with.

Product  approval  NCC  17.0136  X  with  appendices  and
supplements,  as  well  as  IEC  Scheme  Certificate  IECEx
PTB 07.0052X.

See http://www.intertec.info

3

Special conditions for safe use

1. The connecting cable must have a fixed installation

and must be protected mechanically.

2. If connection is made in the potentially explosive

area, the connecting lead shall be connected by
means of an enclosure that meets the requirements
of a type of protection specified in ABNT NBR IEC
60079.

3. Installation shall be made with due regard to the

maximum permissible temperatures of neighbouring
components.

4. The maximum admissible ambient temperature, the

self-heating rate and, if required, the thermal
conduction (medium) shall be considered in
determining the operating temperature (max. 180°C).

5. Additional conditions for alternate use of

thermostats, see concerning test certificate. They
have to be separately certified to the same
standards.

6. Special conditions for some connecting cables have

to be included in the operating manual and have to
be noticed by the installer.

7. lf used in dust-ex-areas the concerning requirements

of ABNT NBR IEC 60079-14, of ABNT NBR IEC
60079-17 and ABNT NBR IEC 60079-19 have to be
considered.

8. The manufacturer's operating manual shall be

observed.

4

Explanation of symbols for warnings
and signal words

The  safety  information  warns  the  user  about  risks  and
provide information on how risks can be avoided.

Safety  information  can  be  found  at  the  start  of  the
chapter  before  the  instructions  which  may  lead  to  a
hazardous situation. Additional safety information can be
found at the beginning of this manual.

Safety  instructions  which  must  be  adhered  to  are
highlighted as follows:

 DANGER

DANGER

This sign is warning about an extremely hazardous
situation which, if not heeded, will lead to death or
serious irreversible injury.

 WARNING

WARNING

This sign is warning about a hazardous situation which,
if not heeded, may lead to death or serious irreversible
injury.

Содержание CP VARITHERM DBPA

Страница 1: ...Operating Instructions CP VARITHERM DBPA HOM146742411Ien 6 17 12 2020...

Страница 2: ...al 3 2 Use 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Installation accessories 4 7 Technical Data 4 8 Installation 5 9 Conn...

Страница 3: ...use 1 The connecting cable must have a fixed installation and must be protected mechanically 2 If connection is made in the potentially explosive area the connecting lead shall be connected by means o...

Страница 4: ...4 M 6x12 hexagon bolts Piece Description 2 T head bolt type 28 15 M 6x15 2 M6 flat hex nuts 2 Washer shape A 6 4 4 Lock washers shape J 6 4 1 M 6x25 threaded rod shape A If one of the components liste...

Страница 5: ...The label needs to remain legible If an additional TAE thermostat is switched in series then it can be attached to the surface of the heater thermal coupling The minimum distance also needs to be adh...

Страница 6: ...al bonding is required The terminal block designated for this purpose has the ground sign In a TT or TN system a residual current device RCD must be used where the measured triggering residual current...

Страница 7: ...of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of ABNT NBR IEC 60079 17 and ABNT NBR IEC 60079 19 must be complied with 12...

Страница 8: ...9 0 2013 Vers o Corrigida 2 2016 ABNT NBR IEC 60079 1 2016 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0136 X Ex tb IIIC T8...

Отзывы: