 CAUTION

NOTICE

This sign is warning about a hazardous situation which,
if not heeded, may lead to slight, reversible injury.

NOTICE

NOTE

It is essential to pay attention to this safety advice as you
may otherwise incur material damage.

 INFO

Important notes and useful additional information.

5

Safety information

 CAUTION

Risk of injury at the rib ends

The sharp edges on the heating ribs may cause injury if
handled incorrectly.

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

6

Installation accessories

The following are included in the scope of delivery:

Piece

Description

1

Heating unit

2

Angle bracket made of flat steel

1

Packet of screws containing the following:

4

M 6x12 hexagon bolts

Piece

Description

2

T-head bolt type 28/15, M 6x15

2

M6 flat hex nuts

2

Washer shape A 6.4

4

Lock washers shape J 6.4

1

M 6x25 threaded rod shape A

If  one  of  the  components  listed  here  is  not  included  in
the  scope  of  delivery,  then  please  contact  the
manufacturer.

7

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in

compliance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60°C

Max. permitted operating

temperature

- 60 to + 180°C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable,

notch- and oil resistant, 3

x 1,5 mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable,

notch- and oil resistant, 5

x 1,0 mm² Ø8,5 mm

Material

Seawater-proof

aluminium, black

anodized

Mean Time Before Failure

50.000 h

Storage temperature

- 60 to + 80°C

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "P" Length x

Width x Height

220 x 213 x 120

mm

Profile type "P" Length x

Width x Height

220 x 213 x 100

mm

Profile type "P" Length x

Width x Height

220 x 213 x 80

mm

Profile type "P" Length x

Width x Height

220 x 213 x 60

mm

Profile type "P" Length x

Width x Height

220 x 213 x 40

mm

Profile type "P" Height x

Width x Depth

213 x 220 x 100

mm

Содержание CP VARITHERM DBPA

Страница 1: ...Operating Instructions CP VARITHERM DBPA HOM146742411Ien 6 17 12 2020...

Страница 2: ...al 3 2 Use 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Installation accessories 4 7 Technical Data 4 8 Installation 5 9 Conn...

Страница 3: ...use 1 The connecting cable must have a fixed installation and must be protected mechanically 2 If connection is made in the potentially explosive area the connecting lead shall be connected by means o...

Страница 4: ...4 M 6x12 hexagon bolts Piece Description 2 T head bolt type 28 15 M 6x15 2 M6 flat hex nuts 2 Washer shape A 6 4 4 Lock washers shape J 6 4 1 M 6x25 threaded rod shape A If one of the components liste...

Страница 5: ...The label needs to remain legible If an additional TAE thermostat is switched in series then it can be attached to the surface of the heater thermal coupling The minimum distance also needs to be adh...

Страница 6: ...al bonding is required The terminal block designated for this purpose has the ground sign In a TT or TN system a residual current device RCD must be used where the measured triggering residual current...

Страница 7: ...of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of ABNT NBR IEC 60079 17 and ABNT NBR IEC 60079 19 must be complied with 12...

Страница 8: ...9 0 2013 Vers o Corrigida 2 2016 ABNT NBR IEC 60079 1 2016 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0136 X Ex tb IIIC T8...

Отзывы: