background image

www.intertec.info

Operating Instructions CP MICROTHERM DENA

Page 4 / 7

HOM180473483Ien-3

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

5

Installation accessories

The following are included in the scope of delivery:

Piece

Description

1

Heating unit

1

Angle bracket made of flat steel

1

Packet of screws containing the following:

2

Hexagon bolts M 6x12

1

T-head bolt type 28/15, M 6x15

2

M6 flat square nut

1

Washer shape A 6.4

2

Lock washers shape J 6.4

1

M6 hex nut

If  one  of  the  components  listed  here  is  not  included  in
the scope of delivery, then please contact the manufac-
turer.

6

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in compli-

ance with VDE 0298)

max 10 A

Ambient temperature

- 60 to + 60°C

Max. permitted operating

temperature

- 60 to + 180°C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable,

notch- and oil resistant, 3

x 1,5 mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable,

notch- and oil resistant, 3

x 1,0 mm² Ø8,5 mm

Material

Seawater-proof alu-

minium, black anodized

Mean Time Before Failure

50.000 h

Storage temperature

- 60 to + 80°C

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "N" Height x

Width x Depth

155 x 50 x 50

mm

 INFO

You will find the precise technical data for your in-
strument on the label.

7

Installation

NOTICE

Carefully remove

When removing from the packaging and during trans-
port, the connection line must not be stressed or bent.

For free convection, the heater needs to be installed with
ribs  standing  vertically.  The  minimum  distances  to  the
floor and to devices above it must be complied with. The
label needs to remain legible.

If  an  additional  TAE  thermostat  is  switched  in  series,
then  it  can  be  attached  to  the  surface  of  the  heater
(thermal coupling). The minimum distance also needs to
be adhered to here. Refer to the following drawing.

To  ensure  operational  safety,  the  heater  must  operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.

The operating temperatures must be adhered to.

The  connection  cable  must  be  permanently  installed  up
to  the  inlet  into  the  on-site  junction  box,  taking  the  per-
missible bending radius = 5 x outer diameter into consid-
eration.

Содержание CP MICROTHERM DENA

Страница 1: ...Operating Instructions CP MICROTHERM DENA HOM180473483Ien 3 11 02 2020 ...

Страница 2: ... of contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 6 10 Maintenance 6 11 Troubleshooting 6 12 Deinstallation 6 13 Disposal 6 14 Declaration of Conformity 7 15 Further information and service 7 ...

Страница 3: ... cable for frost protection applications or a safety thermostat for maintaining temperature If a TAE is used the respective operating instructions must be complied with Product approval 18 KA4BO 0090X and 18 KA4BO 0089X with appendices and supplements as well as IEC Scheme Certificate IECEx PTB 07 0052X See http www intertec info 3 Explanation of symbols for warnings and signal words The safety in...

Страница 4: ... 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Ø8 8 mm Connecting cable AM Silicone hose cable notch and oil resistant 3 x 1 0 mm Ø8 5 mm Material Seawater proof alu minium black anodized Mean Time Before Failure 50 000 h Storage temperature 60 to 80 C Special voltages with corresponding power adjustment and component selection are possible Profile type N Height ...

Страница 5: ...then permissible Each heater with integrated TS thermostat must be pre ceded by a 10 A fuse or a motor protection switch with short circuit and thermal quick release set to 10 A as short circuit protection When using a heater without in tegrated thermostat the fuse protection can be selected according to the cross section of the supply cable Additional equipotential bonding is required The ter min...

Страница 6: ...clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of KS C IEC 60079 17 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a con tinuity test on the heating circuit Pay attention to the connection diagram and switching point of the thermo stat In the case of overheati...

Страница 7: ...otific ation 2016 54 Ministry of Employment and Labor appendix 7 of notific ation 2016 54 Ministry of Employment and Labor appendix 15 of noti fication 2016 54 KS C IEC 61000 6 4 2014 KS C IEC 60529 Marking 18 KA4BO 0090X 18 KA4BO 0089X Ex d IIC T6 T3 Ex tb IIIC T85 C T100 C T135 C T200 C Neustadt May 14th 2018 Dipl Ing Martin Hess Managing Director 15 Further information and service If the inform...

Отзывы: