General

These  operating  instructions  describe  the  safe  and
proper way to work with the device. The safety informa-
tion  and  instructions  given  as  well  as  the  local  accident
prevention  regulations  and  general  safety  regulations
valid  in  the  area  of  application  must  be  complied  with.
These  instructions  are  a  constituent  part  of  the  instru-
ment and need to be kept in the immediate vicinity of the
device accessible to personnel at all times.

Before  starting  any  work,  the  operating  instructions
should be read in full.

2

Use

The CP..THERM heaters are manufactured according to
Directive  from  Ministry  of  Employment  and  Labor  No.
2016-54  and  are  licensed  for  direct  heating  through
flange-mounting  (conduction)  or  for  room  heating  (con-
vection) in Ex-zone 1 and Zone 2 for instrument categor-
ies  G/  D  in  temperature  classes  T3  to  T6.  You  will  find
the  temperature  class  for  your  device  on  the  label.  See

Technical Data

 section.

The areas of application are:

• Frost protection

• Condensation protection

• Maintaining temperature

The standard design has a room thermostat integrated in
the connecting cable for frost protection applications or a
safety  thermostat  for  maintaining  temperature.  If  a  TAE
is  used,  the  respective  operating  instructions  must  be
complied with.

Product 

approval 

18-KA4BO-0090X 

and 

18-

KA4BO-0089X  with  appendices  and  supplements,  as
well as IEC Scheme Certificate IECEx PTB 07.0052X.

See http://www.intertec.info

3

Explanation of symbols for warnings
and signal words

The  safety  information  warns  the  user  about  risks  and
provide information on how risks can be avoided.

Safety  information  can  be  found  at  the  start  of  the
chapter before the instructions which may lead to a haz-
ardous  situation.  Additional  safety  information  can  be
found at the beginning of this manual.

Safety  instructions  which  must  be  adhered  to  are  high-
lighted as follows:

 DANGER

DANGER

This sign is warning about an extremely hazardous situ-
ation which, if not heeded, will lead to death or serious ir-
reversible injury.

 WARNING

WARNING

This sign is warning about a hazardous situation which,
if not heeded, may lead to death or serious irreversible
injury.

 CAUTION

NOTICE

This sign is warning about a hazardous situation which,
if not heeded, may lead to slight, reversible injury.

NOTICE

NOTE

It is essential to pay attention to this safety advice as you
may otherwise incur material damage.

 INFO

Important notes and useful additional information.

4

Safety information

 CAUTION

Risk of injury at the rib ends

The sharp edges on the heating ribs may cause injury if
handled incorrectly.

Содержание CP MICROTHERM DENA

Страница 1: ...Operating Instructions CP MICROTHERM DENA HOM180473483Ien 3 11 02 2020 ...

Страница 2: ... of contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 6 10 Maintenance 6 11 Troubleshooting 6 12 Deinstallation 6 13 Disposal 6 14 Declaration of Conformity 7 15 Further information and service 7 ...

Страница 3: ... cable for frost protection applications or a safety thermostat for maintaining temperature If a TAE is used the respective operating instructions must be complied with Product approval 18 KA4BO 0090X and 18 KA4BO 0089X with appendices and supplements as well as IEC Scheme Certificate IECEx PTB 07 0052X See http www intertec info 3 Explanation of symbols for warnings and signal words The safety in...

Страница 4: ... 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Ø8 8 mm Connecting cable AM Silicone hose cable notch and oil resistant 3 x 1 0 mm Ø8 5 mm Material Seawater proof alu minium black anodized Mean Time Before Failure 50 000 h Storage temperature 60 to 80 C Special voltages with corresponding power adjustment and component selection are possible Profile type N Height ...

Страница 5: ...then permissible Each heater with integrated TS thermostat must be pre ceded by a 10 A fuse or a motor protection switch with short circuit and thermal quick release set to 10 A as short circuit protection When using a heater without in tegrated thermostat the fuse protection can be selected according to the cross section of the supply cable Additional equipotential bonding is required The ter min...

Страница 6: ...clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of KS C IEC 60079 17 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a con tinuity test on the heating circuit Pay attention to the connection diagram and switching point of the thermo stat In the case of overheati...

Страница 7: ...otific ation 2016 54 Ministry of Employment and Labor appendix 7 of notific ation 2016 54 Ministry of Employment and Labor appendix 15 of noti fication 2016 54 KS C IEC 61000 6 4 2014 KS C IEC 60529 Marking 18 KA4BO 0090X 18 KA4BO 0089X Ex d IIC T6 T3 Ex tb IIIC T85 C T100 C T135 C T200 C Neustadt May 14th 2018 Dipl Ing Martin Hess Managing Director 15 Further information and service If the inform...

Отзывы: