![INTERSPORT ENERGETICS POWER RUN 20.1 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/intersport/energetics-power-run-20-1/energetics-power-run-20-1_manual_2080612018.webp)
18
A) In running state, press "+", "-" or "QUICK SPEED" to adjust the SPEED of the treadmill;
B) In P1-P36, the speed and slope of each program are divided into 16 sections, and each section is divided equally according to the
set time. The adjusted speed and slope are only valid within the current section, and three prompt sounds will be issued three seconds
in advance when switching between sections. The motor stops automatically when the program is running at full 16 segments,
accompanied by a prompt sound;
C) Press the "START" button again when the motor is in operation and the motor will switch between suspension and operation.
Restart under the suspended state, and the recorded run data and process remain unchanged;
5. When the motor is running, press the "STOP" button, the motor will slow down until it stops smoothly, and all Settings will return to
the default state;
6. In any state, pull off the safety lock, and the screen will display "E-07" with a prompt sound, and the treadmill will stop running;
7. The electronic control system is under safety monitoring at any time. If any abnormality is found, the running machine will stop in an
emergency. The screen will display abnormal information with a prompt sound.
8. Body FAT test method: press "PROG" key to select program FAT, "DISTANCE" window to display and set the item number, and
press "MODE" key to select the item number; The "TIME" window on the right shows the parameters for setting the project.
Press the "+" and "-" keys to set the parameters.
A) Serial number F1 (Sexo) : denotes gender;Set parameter range: 1-2, "1" means male, "2" means female, Default value: 1;
B) Serial number F2 (Age) : represents Age; Set parameter range: 1-99 years old, default: 25 years old
C) Serial number F3 (Height) :Setting parameter range: 100-220cm, default value: 170CM;
D) Serial No. F4 (Weight) : denotes Weight; Setting parameter range: 20-150kg, default: 70KG;
E) Serial number F5 (BMI) : indicates that you have completed parameter setting and entered the state of body fat test. Please hold
your hands on the heart rate sensor tablets at the left and right handles and wait for 8 seconds. The parameter display window will
display the body fat rate (BMI) of the subject;For Asians, body fat less than 18 is considered thin, between 18 and 24 is considered
ideal, between 25 and 28 is considered overweight, and over 29 is considered obese. The default value is 24 (this data is for exercise
reference only).
ECO function
:
Press the “ECO” key to enter into ECO mode. The treadmill will increase 3 levels based on the current incline level. The min. incline
level is 3. Press again the “ECO” key to quit the ECO mode. Treadmill will decrease 3 levels based on the current incline, the min.
incline is 0. In every time using, the default of treadmill is not in the ECO mode.
ERP function:
The system defaults to ERP mode. In the state of not running the treadmill, it will enter the sleep state in about 4.5 minutes to save
power consumption. Press any key to wake up the system.
Long press the MODE key for 3S to display "2222", cancel the ERP function, and long press 3S to display "1111" to return to ERP
MODE.
Содержание ENERGETICS POWER RUN 20.1
Страница 1: ...1 ENERGETICS POWER RUN 20 1 ENGLISH MANUAL ...
Страница 13: ...13 Step 5 Put the display on the console and lock the two parts together with 4pcs M8 15 screw ...
Страница 15: ...15 Console Function Instruction Key Definition Display window instruction Display window ...
Страница 33: ...33 GREEK MANUAL ENERGETICS POWER RUN 20 1 ...
Страница 47: ...47 ΛΔΗΣΟΤΡΓΗΔ ΔΝΓΔΗΞΔΗ ΚΟΝ ΟΛΑ Οζόλε ...