background image

 

Safety Instructions 

 

All safety and operating instructions should be read before this product is operated and 

should be retained for further reference.  Please adhere to all the warnings on this product 
and in these operating instructions. Please follow these instructions carefully. 

 

Power.

 Only use the power source indicated on the device. Devices equipped with a 

grounded plug should only be used with a grounded type outlet. In no way should this 
grounding be disconnected, modified or suppressed. 

 

Power Supply Lead. 

To unplug the device always pull by the plug itself, not the power 

supply lead. The power source outlet should always be near the MicroCue main unit and 
easily accessible. Ensure the power supply lead cannot be walked on or damaged by items 

placed on or against it. 

Do not use if the power supply lead is damaged. 

Using the device 

with a damaged power supply lead may expose you to electric shock or other hazards. 

Check the condition of the power supply lead regularly. Contact your dealer or service centre 
immediately for a replacement if damaged. 

 

Keep Away From Harmful Substances

 

 

To prevent the risk of electric shock and fire, do not expose this device to rain, humidity or 
intense heat sources (such as radiators or direct sunlight). Avoid using this equipment in 

environments where there is excessive heat, dust, moisture, chemicals, vibration or  
mechanical shocks.  

 

Slots and Openings. 

These are designed into the device for ventilation and to avoid 

overheating. Always ensure these openings remain clear. 

Do not attempt to insert 

anything into these openings under any circumstances.

 If liquids have been spilled on, 

or objects have fallen into the product it must be checked by a qualified technician before re-
using. 

 
Connections.

 All inputs and outputs (except for power input) are TBTS defined under 

EN60950. 
 

 

DO NOT OPEN SYSTEM DUE TO HIGH VOLTAGE.

 

 

DO NOT IMMERSE IN WATER.

 

 

 

Servicing.

 Do not attempt to service this product yourself.  Should an unauthorised person 

attempt to either open the covers or service our products, it may invalidate your Limited 
Factory Warranty.  In addition, opening or removing covers and screws may expose you to 

electric shocks or other hazards. Refer all servicing to qualified service personnel. 

 

 

 

Содержание MicroCue2

Страница 1: ...Cueing and Presentation Control Specialists MicroCue2 User Manual With New Laser Pointer Handset Do not stare into beam...

Страница 2: ...set and safe use 6 Classic Handset 7 Regulations Compliance 8 Environmental 13 Operating Instructions 13 Programming Special Cues 16 Loss of Signal 17 Trouble Shooting 18 Radio Frequency System 23 Equ...

Страница 3: ...rCue series platform retaining proven features such as the robust case design and the AV industrial grade wireless RF system With 3 buttons the presenter can request to go backwards as well as forward...

Страница 4: ...centre immediately for a replacement if damaged Keep Away From Harmful Substances To prevent the risk of electric shock and fire do not expose this device to rain humidity or intense heat sources such...

Страница 5: ...re 1 MicroCue Connections Diagram Figure 2 MicroCue Rear Panel 12VDC Power Input Mini Jack Headphone Cue Tone Output RF Level Indicator BNC Aerial Connector USB Connections Keyboard Program Input PS2...

Страница 6: ...ss than 1mW green 532nm laser It is 10x brighter than an equivalent red laser It is important to use the laser in a safe manner by highlighting your images on screens It is not advisable to use a lase...

Страница 7: ...to be a very popular and trusted handset with a great open field distance of over 75m Power Consumption LED Status If no cue signals are received from the handset and the cue LED on the handset does n...

Страница 8: ...d and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a res...

Страница 9: ...rds Furthermore we warrant that each unit of equipment marketed is identical to the unit tested and found acceptable with the standards The records maintained continue to reflect the equipment being p...

Страница 10: ...126 Great North Road Hatfield Hertfordshire AL9 5JN United Kingdom EC DECLARATION OF CONFORMITY TO R TTE DIRECTIVE 1995 5 EC Manufacturer Hive Industries Ltd Interspace Industries Product MicroCue2 I2...

Страница 11: ...ctive 1999 5 CE qui lui sont applicables Hiermit erkl rt Interspace Industries dass sich dieser diese dieses MicroCue2 in bereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten...

Страница 12: ...ing standards or other normative documents EN55103 1 EN55103 2 1966 Specific for professional Audio Visual Products Used in environment as defined under E2 Commercial and Light industry example Theatr...

Страница 13: ...U After connecting either power source to the main unit the system will do a short test during which the display on the main unit will flash green once then red once The presenter control selector but...

Страница 14: ...Ground Sleeve No connection Presenter Control Selector Mode The presenter control button has 4 states as follows 1 Both A and B USB channels are selected default 2 Both A and B USB channels are off 3...

Страница 15: ...bled and no cues can be sent to any computers that may be connected Handset Code Erase To erase all handset learn codes 1 Press and hold the Learn button on the underside of the MicroCue2 main unit us...

Страница 16: ...these to a handset button will disable that button MicroCue2 can also be programmed so that channels A and B can respond differ ently using the same handset For example it is possible to program chann...

Страница 17: ...of these points will leave the system ready to receive a new command for that particular button on the handset 5 Once the system is ready to receive a new command for the button you wish to re program...

Страница 18: ...s to work at rehearsal and the room is empty but problems can occur when the room is full As we do not operate on or near 2 4 GHz Bluetooth WIFI we are not usually interfered with by these frequencies...

Страница 19: ...not work there may be a technical problem Battery life Classic Laser The Classic and Laser handsets will stop transmitting if the battery is at a low state as it could cause incorrect transmission whi...

Страница 20: ...utton is in the correct mode Check you have the computer connected to the correct USB port 2 MicroCue2 in two rooms operating each other This is because the handset has been programmed to both the Mic...

Страница 21: ...able only for PC systems running a WINDOWS XP Vista or Win 7 or later operating system To ensure optimum performance we can only recommend using the USB A B type cable supplied Mac Computer USB Interf...

Страница 22: ...u to use a BNC 50 Ohm cable great than 4 Metres As an option you can use a 10M up to 50M cable user supplied and locate the aerial closer to the presenter This will help in those rooms where which are...

Страница 23: ...Transmission method FM Pure FSK Maximum transmit power 10mW EU 11mV m 3m USA This frequency is open and licence exempt for UK Europe and USA Other countries should consult their respective authorities...

Страница 24: ...24 Unit 1a 126 Great North Road Hatfield Hertfordshire AL9 5JN United Kingdom Tel 44 0 870 770 8088 Fax 44 0 870 770 8089 Email moreinfo interspaceind com www interspaceind com...

Отзывы: