
Interroll Roller curve SH 1210
Installation
Version 1.0 (06/2022) en
Translation of original operating instructions
27
Installing the photo cell and reflector
The photo cell and reflector are each delivered as a complete unit:
• The photo cell is in the photo cell housing.
• The reflective tape is affixed to the reflector.
WARNING
Risk of injury from crushing and electrocution
Installation and maintenance tasks on a conveyor system while it is in operation can cause
crushing and electric shock.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Photo cell and reflector can be installed along the C-profile of the side frame. The flexible
universal support enables adjusting the sensors with respect to height and distance and correctly
align them to each other.
Fasten screws with a tightening torque of 19 Nm.
Photo cell and reflector must be installed exactly facing each other: