Operating Adjustments

 

 

R

ange/Depth Adjustment

 

 

To change the Depth or Forward Range, press the 

button labeled 

RANGE to bring up the Range 

Adjustment menu.  You can use the up/down NAV 

buttons to increase or decrease the range.  

 

The 

Range adjustment menu in the Vertical and 

Horizontal mode is different.   In the Horizontal mode, 

the forward range and depth can be adjusted 

independently, however when in the Vertical mode, the 

forward range and depth are related by a fixed ratio of 

2:1 (the aspect ration of the display) or, if 

Depth  

Expansion has been selected, a ratio of  4:1.   

Therefore, in the vertical mode, changing the forward 

range will also change the depth range. 

 

If you are in the hozizontal split screen modes with the 

DOWN looking depth showing on the left, you can 

adjust the downlooking depth range (Down)  

and/or 

the forward looking scanning range.   To adjust the 

downlooking depth range, press the left side of the 

NAV button to select the DOWN depth adjustment (a 

red box will indicate it is selected).  To adjust the range 

up or down, press the up or down arrow on the 

NAV 

Button.  

 

If the 

AUTO softkey is pressed, a red box will indicate 

the feature is selected and the depth range will 

automatically change to track the bottom.  Note: when 

the unit is in the vertical scan mode, the vertical range 

will also change each time the depth range changes, 

however when in the horizontal scan mode only the 

depth range will change. 

 

The Range menu in the vertical scanning modes also 

includes an icon in the middle that resembles a 

magnifying glass.   Pressing the softkey for this icon 

will change the aspect ratio of the screen from 1:2 to 

1:4.  Use this feature to 

expand the vertical scale (by a 

factor of two) allowing longer forward ranges in 

shallow water without the bottom depth being 

compressed at the top of the display. A red box around 

the icon indicates this feature is selected, pressing the 

softkey for this icon again will return the display to the 

normal 1:2 aspect ratio. 

 

 

13.2 Ft

18

37

25

12.5

 

400 

100 

Use 

NAV 

buttons 

to change from Depth to 

Forward Range 

 

400 

100 

13.2 Ft

18

37

25

12.5

 

400 

 

 

400 

100 

Selecting Auto Depth Ranging 

Selecting Depth  

Range Expansion 

Содержание Sonar Engine SE-200

Страница 1: ...1 SE 200 SONAR ENGINE...

Страница 2: ...ly follow the steps outlined in this manual An instructive demonstration simulator has been designed into the SE 200 and we highly recommend that you spend some time using the demo mode prior to actua...

Страница 3: ...Display 15 Set Up 17 Languages Units 17 More Max Vert Gain Boat Icon 17 STC Adjustment 17 Software Setup 18 Keel Offset Transducer Level Adjust 18 Demo 19 System Reset 19 Installation 20 Engine Box Co...

Страница 4: ...ansducers These systems are identified as 1 SE 200A With thru hull or transom mount vertical scanning transducer This configuration scans a 90 degree forward vertical segment and looks down but does n...

Страница 5: ...ay the softkey buttons are directly below the display menu For simplification in this manual menu choices are shown with a finger pointing to a menu icon like the alarm icon at right This actually mea...

Страница 6: ...sel The current depth directly below the boat is shown at the top left of the display just in front of the boat icon The current forward range is shown by the digital number at the far top right of th...

Страница 7: ...While in the Forward Horizontal Down Split mode or if you select the Full Screen Down mode while in the Horizontal mode the Depth Range can be adjusted independantly from the Forward Horizontal range...

Страница 8: ...s in large digits on the left side of the display see drawing at left In order for the SE 200 to show the speed and Lat Lon coordinates the unit must be connected to an NMEA source of this data such a...

Страница 9: ...ndicate it is selected To adjust the range up or down press the up or down arrow on the NAV Button If the AUTO softkey is pressed a red box will indicate the feature is selected and the depth range wi...

Страница 10: ...u can also turn off the AUTO GAIN feature by pressing the AUTO softkey again To exit the GAIN MENU and save your adjustments simply press the exit symbol or allow the menu to time out approx 6 seconds...

Страница 11: ...le as shown in the diagram at right Notice that the beam expands as it gets further from the boat For example at 1 000 feet the beam angle has a diameter of greater than 100 feet However the cursor ca...

Страница 12: ...Use the NAV buttons to adjust the beam sector size and then use the NAV left right buttons to adjust the resulting sectors direction Press the EXIT softkey to save the setting and exit or press the cl...

Страница 13: ...sequentially steps the acoustic beam from directly forward to the bottom the display shows a continuously updated display of the return echoes in their approximate position in relation to the vessel...

Страница 14: ...anted transducer sidelobe readings Transducer Sidelobe Effect The SE 200 s transducer like all acoustic transducers does not form a perfect beam of acoustic energy Some of the acoustic energy is conta...

Страница 15: ...ttom ahead of the boat but the bottom echos can also mask or be confused as fish targets The center picture and resulting screen display shows a boat in 14 7 feet of water The SE 200 s forward range i...

Страница 16: ...at Various Forward Ranges Beam Depth Approx 0 18 X Forward Distance In certain conditions especially in shallow water you may see a horizontal display that shows a target ahead that remains on the scr...

Страница 17: ...are To adjust the MAX VERT GAIN use the softkey to highlight the desired range then use the NAV UP DOWN buttons to adjust the Max Gain When finished with all settings press the EXIT symbol to save you...

Страница 18: ...ine as shown Use the NAV key to adjust up or down to ignore the clutter area and then press the EXIT symbol to save and return to a normal display After making this adjustment the surface clutter will...

Страница 19: ...ownward as in the pictures at left note the approximate angle of the unwanted upward or downward slope on the display Then proceed to the TRANSDUCER adjustment menu as above and press the softkey butt...

Страница 20: ...end The sketch at right shows the three 9 pin transducer con nectors that are located on the left end panel The three connector retaining nuts are different colors which match the color band on the co...

Страница 21: ...the box including turning power ON OFF The keypad should be mounted conveniently close to the display preferable directly beneath so the keypads softkeys are easy to relate to the displays softkey me...

Страница 22: ...even further cable lengths and improved quality with multi ple displays Amplified splitter information is available from Interphase Technical Support at 831 477 4944 ext 16 or with the SE 200 informat...

Страница 23: ...E DISPLAY WITH INTERGRAL KEYPAD VGA CABLE SPLITTER P N 04 1095 000R Female to two Males 30 TRANSDUCER MULTIFUNCTION OR VIDEO ENABLED DISPLAYS For Furuno Video Displays See Next Page 30 TRANSDUCER 30 T...

Страница 24: ...E STATION CONNECTING TO VGA DISPLAYS VGA Splitter P N 04 1092 000R Female to two Males AMPLIFIED VGA CABLE SPLITTERS Some paralleled VGA monitors cause a reduction in VIDEO signal and picture brightne...

Страница 25: ...ths over 60 are not recommended as they will decrease the effective power and depth range Choose a location where there is the least amount of acoustic noise air bubbles or turbulence caused by the bo...

Страница 26: ...transducer may be placed forward of the keel ahead of the lifting strap location This should not be ahead of 1 3 aft of where the bow meets the waterline On planing hulls the transducer is typically...

Страница 27: ...ing blocks will expand after the boat is put back into the water so it is important that the transducer be only hand tightened until the wood fully expands Otherwise the wood fairing block may crack S...

Страница 28: ...tallation for any leak to appear Use of a Thru hull Fairing Block Nearly all vessels have some dead rise angle at the transducer mounting location If the thru hull transducer were mounted directly to...

Страница 29: ...icks up and becomes non operational The bracket does not automatically reset at lower speeds The transducer must be manually returned to its operational position Special Note The kick up feature is de...

Страница 30: ...und the transducer cable and slide it into the slot in the spray shield The bracket arms must be mounted outside the stainless steel mounting ears of the transducer Do not fully tighten the lock nuts...

Страница 31: ...t Axle Assembly On some boats it will be neccessary to remove the Bracket Axle during installation See the diagram to the left and instructions below for details on assembling the axle 1 Place one sta...

Страница 32: ...ould be connected between the Orange and Blue wires in the power and I O cable from the red sonar box and the Temperature and Speed source should be connected between the Brown and Blue wires The SE 2...

Страница 33: ...nector on the internal PCB Connect the Mini USB B small connector to this USB connector and then connect the other end of the cable to the USB port of your PC Then turn ON the SE 200 sonar engine by u...

Страница 34: ...1 SCAN VGA Includes 10 9 Pin to VGA Adapter Cable KEYPAD With 10 Cable 23 1015 000 30 9 Pin Male to Female 10 9 Pin Male to Female INTERPHASE 7 DISPLAY With Integral Keypad 04 0014 008 04 0014 007R VG...

Страница 35: ...paint 5 DO NOT allow any solvents i e gasoline acetone to come in contact with the transducer or head unit as these may dissolve the material Troubleshooting Tips PROBLEM POSSIBLE SOLUTION Unit will...

Страница 36: ...er Requirements 11 to 16 VDC less than 0 5 Amp Operating Temperature 0 to 50 degrees C 32 to 122 degrees F NMEA 0183 Inputs GLL VTG NMEA 0183 Output DBT DPT Standard Equipment Red sonar box keypad wit...

Страница 37: ...all an alternator filter to smooth the alternator s output signal Interference may also be caused by radiation from other nearby equipment and can be detected by turning off all other equipment and ob...

Страница 38: ...38 Notes...

Страница 39: ...t to extreme conditions beyond control of the manufacturer and Interphase Due to these conditions the warranty on these components is limited to one year against defects in workmanship or materials Th...

Страница 40: ...40 2880 Research Park Dr Suite 140 Soquel CA 95073 PHONE 831 477 4944 FAX 831 462 7444 comments interphase tech com www interphase tech com...

Отзывы: