background image

25 

Operating Adjustments

 

 

Range Adjustment 

 

To change the Depth or Forward Range, press the button 

labeled 

RANGE to bring up the Range Adjustment soft key 

menu.  You can use the 

NAV or UP/DOWN button to adjust 

the 

RANGE upwards or downward.   

 

If you are in one of the split screen modes with the 

DOWN 

looking depth showing on the left, you can adjust the 

downlooking depth range (Down)  

and/or the forward 

looking scanning range.   To adjust the downlooking depth 

range, press the left side of the 

NAV button to select the 

DOWN depth adjustment (a red box will indicate it is 

selected).  To adjust the range up or down, use the 

NAV 

Button or the 

UP/DOWN button. 

 

To adjust the forward looking Range, use the Right side of 

the 

NAV button to select the SCAN range adjustment (a red 

box will indicate it is selected).  To adjust the range up or 

down, use the 

NAV button or the UP/DOWN button. 

 

When finished, press the 

EXIT softkey or allow the menu to 

time-out after a few seconds. 

 

 

 

Gain Adjustment (Sentivity) 

 

Press the button labeled 

GAIN to bring up the choices 

available for adjusting the 

iScan V90's receiver GAIN.  Press 

the button below 

AUTO so that the word AUTO is shown 

with a red border if you would like the 

Color Twinscope to 

automatically adjust its receiver gain for changing conditions.  

To manually adjust press the  

 on the 

NAV or UP/

DOWN button to increase or decrease the receiver gain. Note 

that the 

GAIN MENU shows a number which indicates the 

relative sensitivity being used (+1 to +32).  When you choose 

to manually adjust the 

GAIN, the Color Twinscope turns off 

the 

AUTO mode and it will remain off until the AUTO soft 

key is again selected. Note:  when 

AUTO mode is turned on 

the word  will be displayed with a red border. . To exit the 

GAIN MENU and save your adjustments simply press the 

exit symbol or allow the menu to time-out (approx. 12 

seconds)  

 

 

CURSR

VERT

VIDEO

DOWN

DATA

RANGE

GAIN

PWR

FORWARD LOOKING SONAR

13.2 Ft

18

37

25

12.5

 

DEPTH:    25 

FWD RANGE: 50

   

 

DEPTH:    25 

FWD RANGE:  50

   

 

AUTO 31 DOWN 

AUTO 15 SCAN 

CURSR

VERT

VIDEO

DOWN

DATA

RANGE

GAIN

PWR

FORWARD LOOKING SONAR

13.2 Ft

18

37

25

12.5

 

 31 DOWN  AUTO 15 SCAN 

AUTO

 

Setting 

AUTO mode. 

Use 

NAV 

buttons to change 

from Depth to 

Forward Range 

Adjustment. 

Use 

NAV 

buttons to change 

from Down to 

Forward Scan 

Gain  Adjustment. 

Содержание iScan V90

Страница 1: ...1...

Страница 2: ...ant to us To this end we welcome any comments or suggestions that you might have in regard to this equipment It is very important that you complete and return the WARRANTY REGISTRATION CARD within 15...

Страница 3: ...ducer Adjustments 21 Demo 21 System Reset_____________________________________________________________21 Displays 22 Vertical 22 Down 23 Down Zoom 23 Data 24 Operating Adjustments 25 Range 25 Gain 25...

Страница 4: ...can be fully protected Should you experience a problem with your iScan V90 first refer to the Troubleshooting section page 34 of this manual Most common problems and their solutions are described her...

Страница 5: ...irected in an almost unlimited number of directions For example using an 8 element phased array transducer the iScan V90 is capable of steering the acoustic beam in any of 60 different directions Sinc...

Страница 6: ...e so that it does not run parallel or close to the transducer cable engine refrigeration bilge pump or any other critical wiring An in line fuse holder is included with your unit and should be placed...

Страница 7: ...unting the mounting base portion of the Quick Disconnect Mount is removed To remove the mounting base loosen the thumb screw until it seperates from the upper portion of the Quick Disconnect Mount Whi...

Страница 8: ...Main Power I O Wiring Cable from Quick Disconnect Bracket WIRE COLOR DESCRIPTION FUNCTION BLACK GND COMMON POWER SUPPLY GND RED POWER 11 16 VDC POWER SUPPLY WHITE RXA GPS INPUT PORT GREEN RX TX GND S...

Страница 9: ...ternatley the transducer may be placed forward of the keel ahead of the lifting strap location This should not be ahead of 1 3 aft of where the bow meets the waterline On planing hulls the transducer...

Страница 10: ...FORMANCE MAY BE SERIOUSLY DEGRADED THIS ACTION WILL VOID YOUR WARRANTY If you need a longer length cable than comes with the transducer 30 then purchase the optional 30 extension cables Interphase Par...

Страница 11: ...ts that regularly exceed 35MPH 30 knots Boats that exceed 40MPH 35knots cannot use transom mounted transducers but instead must use thru hull transducers Special Note The kick up feature is designed a...

Страница 12: ...acer with the mounting holes of the mounting bracket and slide the axle in place through the spacer 5 Place one small stainless steel spacer against the transducer bracket 6 Slide two urethane spacers...

Страница 13: ...sducer so that it is perpendicular from side to side and make sure the rounded shaped area is pointed towards the front of the boat Mounting the Transducer to the Boat After you have selected the opti...

Страница 14: ...ration of the transducer can be minimized by keeping the transducer mounted away from the keel and by not mounting too far forward b On sailboats the transducer should be mounted where the acoustic be...

Страница 15: ...d rise angle at the transducer mounting location If the thru hull transducer were mounted directly to the hull the sound beam would be tilted off the vertical at the same angle as the dead rise Most t...

Страница 16: ...s sealant Carefully confirm that the transducer is aligned so that the round front end is pointed directly toward the front of the boat 7 Install and tighten the bronze hex nut allow for swelling in w...

Страница 17: ...ng the brightness The screen menu provides visual feedback on the adjustment and often allows further choices by pressing one of the 5 softkeys below the menu If no button is pressed for several secon...

Страница 18: ...P MENU where you can select languages change the display units select a boat icon customize the system gain settings adjust the NMEA baud rate set a transducer keel offset add a compensation for the t...

Страница 19: ...L GAIN range choose the boat icon configure the display as either a MASTER or REMOTE or press MORE to adjust the STC to minimize the effect of surface clutter To choose the boat icon and the MASTER 1...

Страница 20: ...not used to calculate the digital depth or sound an alarm If you are having problems with the digital depth or alarms because of excessive surface clutter you can increase or decrease the exclusion ra...

Страница 21: ...ate angle of the unwanted upward or downward slope on the display Then proceed to the TRANSDUCER adjustment menu as above and press the softkey buttons to adjust the Level L It is possible to adjust 1...

Страница 22: ...y should look similar to the unit shown at right The boat icon at the top left of the display represents the position of the vessel The horizontal line with the scale across the top of the display rep...

Страница 23: ...lay you can ZOOM into any 25 portion of the depth being displayed For example if the downlooking depth range is 100 feet then the ZOOM function can be used to look at any 25 of the depth like 10 to 35...

Страница 24: ...and Lat Lon coordinates in large digits on the left side of the display see drawing at right In order for the Color Twinscope to show the speed temperature and Lat Lon coordinates the unit must be con...

Страница 25: ...choices available for adjusting the iScan V90 s receiver GAIN Press the button below AUTO so that the word AUTO is shown with a red border if you would like the Color Twinscope to automatically adjus...

Страница 26: ...e CURSOR DATA BOX will display the approximate DEPTH and RANGE from the vessel to that location It is important to realize that the depth information in the CURSOR DATA BOX is the result of a calculat...

Страница 27: ...below the symbols in the ALARM MENU or the NAV or UP DOWN button Press the softkey button below the EXIT symbol to save the setting and exit or press the button below the CLEAR symbol to disable the A...

Страница 28: ...em in a full screen format on the iScan V90 s display If more than one camera or video input is required you can use a video switch to choose between several video signals Pressing the softkey button...

Страница 29: ...e position in relation to the vessel Because the LCD display is only showing the acoustic echoes that are returned to the transducer it can not show forward bottom conditions that are hidden from its...

Страница 30: ...ustic energy Some of the acoustic energy is contained in an area called the sidelobes In conventional downlooking depthsounders the sidelobes create little problem except to distort the size of the ac...

Страница 31: ...n V90 the View Cam and the Fish Cam The View Cam is splash proof and is ideal for mounting in engine rooms or to monitor deck areas The View Cam is designed to fit into a plastic thru hull and has a w...

Страница 32: ...nds out the following NMEA 0183 sentences with the digital depth data DPT DBT Software Upgrades You can download software updates to your PC from our website at www interphase tech com and then upload...

Страница 33: ...from the Master 1 connects to the Yellow wire from the Remote 2 and the Yellow wire from the Master 1 connects to the Orange wire from the Remote 2 The Green wires from both units are tied together O...

Страница 34: ...int 5 DO NOT allow any solvents i e gasoline acetone to come in contact with the transducer or head unit as these may dissolve the material Troubleshooting Tips PROBLEM POSSIBLE SOLUTION Unit will not...

Страница 35: ...all an alternator filter to smooth the alternator s output signal Interference may also be caused by radiation from other nearby equipment and can be detected by turning off all other equipment and ob...

Страница 36: ...ing Rates Automatically optimized for selected range Power Requirements 11 to 16 VDC less than 1 2Amp Operating Temperature 0 to 50 degrees C 32 to 122 degrees F NMEA 0183 Inputs GLL VTG MTW NMEA 0183...

Страница 37: ...ite 140 Soquel CA 95073 In addition to speed your repair please fill out the following tear this page out of the manual or photocopy it and tape it to your unit for our technicians to review A copy of...

Страница 38: ...38 Notes...

Страница 39: ...t to extreme conditions beyond control of the manufacturer and Interphase Due to these conditions the warranty on these components is limited to one year against defects in workmanship or materials Th...

Страница 40: ...40 2880 Research Park Dr Suite 140 Soquel CA 95073 PHONE 831 477 4944 FAX 831 462 7444 comments interphase tech com www interphase tech com...

Отзывы:

Похожие инструкции для iScan V90