2.0 SYSTEM COMPONENTS
The ISI 2500 and ISI 3500 comes standard with:
(1) Thermal Imaging Camera
(2) Rechargeable NiMH Batteries
(1) External Battery Charger Kit
(1) Internal Battery Charger Kit
ISI 2500 ThERMAL IMAGER
CONFIGURATION: Hand held
CASE CONSTRUCTION: Ultem
DIMENSIONS: Height 5.25 inches with visor
Width 6.25 inches
Length 8 inches
SENSOR: Amorphous Silicon Microbolometer
ARRAY SIZE: 160 x 120
WEIGHT: 3.8 lbs with battery
POWER SOURCE: 7.2 V, 4.5 Ah Rechargeable NiMH
Battery
OPERATING TIME: minimum 4 hours
FIELD OF VIEW: 50º x 35º
ThERMAL SENSITIVITY: ‹ 100mK
VIDEO OUTPUT: EIA, 525 lines, 60Hz.
1.0 SPECIFICATIONS
ISI 3500 ThERMAL IMAGER
CONFIGURATION: Hand held
CASE CONSTRUCTION: Ultem
DIMENSIONS: Height 5.25 inches with visor
Width 6.25 inches
Length 8 inches
SENSOR: Amorphous Silicon Microbolometer
ARRAY SIZE: 160 x 120
WEIGHT: 3.8 lbs with battery
POWER SOURCE: 7.2 V, 4.5 Ah Rechargeable NiMH
Battery
OPERATING TIME: minimum 4 hours
FIELD OF VIEW: 50º x 35º
ThERMAL SENSITIVITY:
‹
50mK
VIDEO OUTPUT: EIA, 525 lines, 60Hz.
(1) Operation Manual
(1) Warranty Card
(1) Of the following:
Kevlar
®
Neckstrap
Kevlar
®
Short Lanyard
Retractable Lanyard
3.1 Battery Installation & Removal
3.1.1 To install the battery, hold the camera firmly
in a comfortable position and line up the rails of the
battery with the tracks on the bottom of the camera
and slide it into place. Check for proper seating of the
battery by ensuring the forks of the release button on
the battery are not visible. If forks are visible, push
battery in, and forks up, until forks disappear.
CAUTION:
Visible battery forks will increase
likelihood of battery detachment should camera be
dropped or slammed.
3.1.2 To remove the battery, hold the camera firmly
in a comfortable position and while pushing the
release button away from the camera slide the battery
completely off. Be sure the forks of the release button
are entirely disengaged before sliding.
CAUTION:
If forks are not entirely disengaged,
forks can become damaged rendering the battery
non-usable.
3.0 GENERAL OPERATION
WARNING: When in a hazardous environment,
the camera MUST BE TURNED OFF PRIOR TO
ChANGING BATTERIES. The camera is NOT
intrinsically safe.
Replacement batteries must be purchased
from the manufacturer’s distributor or the
manufacturer. Use of unapproved batteries or
chargers may result in system malfunction or
failure, which could lead to injury or death.
WARNING: Do not use camera without the
battery deflector in place.
NOTE:
Leaving battery attached to camera without
internal charger connected will drain battery. Do not
leave internal charger connected to camera without
charger being plugged into a power source.
NOTE: When using EchoSeeker, refer to EchoSeries
manual.
battery deflector
!
!
!
!