REMOTE CONTROL 

Handling and location of the remote controller 

 

Use the remote control at a distance of 16 ft., or less, from the appliance. Point it towards the receiver on the air 
conditioner. Communication is confirmed with a beep.

 

CAUTIONS 

 

The air conditioner will not operate if curtains, doors or other materials block the signal from the remote control to 
the air conditioner. 

 

Avoid 

o

 

Liquids 

o

 

Direct Sunlight 

o

 

Extreme Temperatures 

 

If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function 
properly.  

 

If other electrical appliances react to the remote controller, either move these appliances or consult your local 
dealer. 

 

Replacing Batteries

 

The remote control is powered by two AAA alkaline batteries housed in the back of the remote. (Do not use 
rechargeable batteries). 
(1)  Remove the cover by pressing down and sliding back. 
(2)  Remove the old batteries and insert the new batteries, observing polarity. 

(3) 

Replace the battery cover.

 

NOTE

When the batteries are removed, the remote control erases all settings. After inserting new batteries, the 

remote control settings must be reselected.

 

 

Remote Control Specifications 

 

Rated voltage 

3.0V 

Lowest operating voltage 

2.4V 

Signal receiving range 

16 ft 

Temperature range 

23-140

 

NOTE: 

· 

The remote control is a sending device only. The display on the control panel of the air conditioner will 
indicate changes made by the remote control. 

· 

The illustrations in this manual are for explanation purposes only. The actual shape of remote controller may 
be slightly different.  

 
 
 
 
 
 
 
 
 
 
 

Содержание STW410AYX

Страница 1: ...NUAL 950 0184 revB 3 12 2014 FOR MODELS COOLING CAPACITY HEATING CAPACITY TTW48A115X STW48AYX 8 000 N A TTW410A115X STW410AYX 10 000 N A TTW412A115X STW412AYX 12 000 N A TTW412A230X STW412AZX 11700 12...

Страница 2: ...es described in this manual but will not affect proper operations and usage Please read carefully the sections corresponding to the specific model you have and keep the manual in a safe place for refe...

Страница 3: ...isting practices but should be considered as supplemental information Transportation Damage The carton should be checked upon arrival for any external damage If damage is found immediately contact sel...

Страница 4: ...o turn the unit on or off Always make sure the RESET button is pushed in for correct operation The power supply must be replaced if it fails reset when either the TEST button is pushed or it cannot be...

Страница 5: ...t be in structurally sound and have a rear grille that securely attaches to sleeve Wall sleeve 4230050 is not shipped with chassis and must be purchased separately CAUTION When installation is complet...

Страница 6: ...mmet mounted compressor These grommets are factory set and require no adjustment Check for obstruction to air flow correct if necessary The unit must be located where curtains furniture trees or other...

Страница 7: ...evious directions are the preferred way to mount the new rear grill The unit performance is slightly better and the possibility of draughts is reduced Another option is direct mounting of the grille t...

Страница 8: ...84 long stuffer seal foam insulation between the wall sleeve and the unit 2 Assemble the trim frame by inserting top and bottom pieces into side pieces and snapping into place 3 Pull cord through tri...

Страница 9: ...panel and remote as shown below and all its functions then follow the symbol for the functions you desire The air conditioner can be controlled by the remote control or the control panel Cooling Only...

Страница 10: ...button is pressed the fan speed mode is shifted If the DRY mode is selected the fan will operate in Low speed Heat Mode Heat Model Only Press the Mode button to select heat function Press Up or Down...

Страница 11: ...ale air Fan speed is selectable Auto High Med and Low The Fan only function will display the actual room temperature In other modes the set point is displayed If the Fan Auto is selected the temperatu...

Страница 12: ...r setting to 0 0 will cancel the Auto Start Stop timed program CHECK FILTER FEATURE This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illuminate after...

Страница 13: ...ealer Replacing Batteries The remote control is powered by two AAA alkaline batteries housed in the back of the remote Do not use rechargeable batteries 1 Remove the cover by pressing down and sliding...

Страница 14: ...Press this button and the system will automatically shift to COOL operation with auto fan speed The setting temperature is 80 F and the timer setting program will be cancelled SLEEP button Press this...

Страница 15: ...s selected the temperature is automatically set to 75 F The fan speed will decrease as the room temperature approaches set point Auto operation Ensure the unit is plugged in and power is on 1 Press th...

Страница 16: ...ion Press this button to activate the SLEEP mode This function is available on COOL HEAT or AUTO mode only and maintains the most comfortable temperature for you In this mode the selected temperature...

Страница 17: ...ir conditioner Timer operation Combined Setting both ON and OFF timers simultaneously AUTO STOP AUTO START On Stop Start operation This feature is useful when you want to stop the air conditioner afte...

Страница 18: ...tioner will not operate properly Air Directional Louvers NORMAL SOUNDS When your air conditioner is operating normally you may hear sounds such as Droplets of water hitting the condenser causing a pin...

Страница 19: ...s very dirty wash it in warm water with a mild detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency C...

Страница 20: ...nutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Reset butto...

Страница 21: ...to the outside are open Close all windows and doors The Vent control is set to open on some models Push the Vent control to CLOSED for maximum cooling and or heating The temperature set point or Ther...

Страница 22: ...Minimum Circuit Breaker Size 15 A 15 A 15 A 15 A 20 A Minimum Circuit Capacity 15 A 15 A 15 A 15 A 20 A Refrigerant Charge R410a oz 12 7 14 81 19 8 17 64 16 93 Design Pressure High 520 PSIG 520 PSIG 5...

Страница 23: ...ee replacement of defective parts only Labor and Refrigerant are not covered under this warranty Replacement as a result of normal wear or mishandling is not covered under this warranty Additional cla...

Отзывы: