International Refrigeration Products DH450 Скачать руководство пользователя страница 14

 

- 13 -

TROUBLESHOOTING 

USE THE CHART BELOW TO DETERMINE OPERATIONAL ISSUES THAT MAY NEED 

SERVICE 

 

PROBLEM POSSIBLE 

CAUSES 

SOLUTIONS 

Dehumidifier does 
not start. 

Power cord is unplugged. 

Verify that outlet is working, and that plug 
is firmly plugged into the outlet. 

Blown fuse or circuit breaker. 

Check and replace/reset circuit breaker. 

Water tank is full. 

Empty water tank and replace. 

Water tank is not installed 
properly. 

Verify that water tank is installed properly. 

Dehumidifier does 
not dry the air as 
it should. 

Unit was not allowed enough 
time to remove moisture. 

Allow at least 24 hours to maintain a 
desired dryness level. 

Airflow is restricted. 

Make sure intake louvers aren't blocked, 
and have proper clearances. See 
“Choosing a Proper Location” section. 

Dirty filter. 

See “Maintenance” section. 

Doors and windows may not 
be closed tightly. 

Check that doors, windows, and other 
openings are securely closed. 

Humidity may be entering the 
room via other sources IE 
Clothes dryer, etc. 

Look for sources of Humidity and correct if 
necessary 

Ambient temperature to low. 

Moisture removal is best at higher room 
temperature. Lower room temperatures 
will reduce the moisture removal rate. Unit 
is designed to be operated at 
temperatures above 41°F. 

Dehumidifier runs 
too much. 

Area to be dehumidified is too 
large. 

The capacity of your dehumidifier may not 
be adequate. 

Doors and windows are open. 

Close all doors and windows to the 
outside. 

Frost appears on 
the coils. 

Dehumidifier has been recently 
turned on, or room 
temperature is below 41 °F 

This is normal. Frost will usually disappear 
within 60 minutes. See the “Auto Defrost” 
section. 

Fan Noise. 

Air is moving through the 
Dehumidifier 

This is normal. 

Water leakage. 

Tank Drain hose may be loose

Check hose connection and tighten if 
necessary 

Water Tank not installed 
properly 

See “Using the Water Tank” section on 
page 10. 

F2 on Display 

Defrost Sensor Error 

Call Service Technician. 

 
 
 
 

Содержание DH450

Страница 1: ...DEHUMIDIFIER USER MANUAL For Models DH450 DH450S DH470 DH470S 950 0141 revA 11 21 11...

Страница 2: ...l but will not affect proper operations and usage Please read carefully the sections corresponding to the specific model you have and keep the manual in a safe place for reference The refrigerant used...

Страница 3: ...icates the possibility of injury or damage to property only WARNING Follow all grounding and electrical requirements as shown on page 4 Turn unit OFF and disconnect power cord from receptacle prior to...

Страница 4: ...place water tank after emptying to prevent water damage to property and unit Do not operate unit with wet hands Close all doors and windows to the room where the dehumidifier is to be operated Dehumid...

Страница 5: ...a dedicated circuit serving only this appliance For your personal safety this appliance must be grounded This appliance has a power supply cord with a grounding plug To minimize possible shock hazard...

Страница 6: ...culation Place the dehumidifier in an area where the temperature will not fall below 41 F 5 C The coils can frost over at temperatures below 41 F which may reduce performance Use the dehumidifier in c...

Страница 7: ...6 OPERATION UNIT OUTLINE NOTE The appearance of the units that you purchased might be slightly different from shown above...

Страница 8: ...l is defrosted the compressor or fan will automatically restart and resume operating ALARM If the water tank is full or not installed for more than three minutes an alarm will beep every 10 seconds to...

Страница 9: ...a hose to drain or until the bucket is full For drier air press the pad and set to a lower percent value For damper air press the pad and set to a higher percent value For the initial use or the humi...

Страница 10: ...gh fan speed which is suitable for maximum dehumidification Medium Press the Fan Speed button until the indicating light for this speed is illuminated The unit will start to operate in Medium fan spee...

Страница 11: ...G THE WATER TANK When the tank is removed the unit will shut off Empty and replace the water tank into unit If the water tank is not replaced properly the Full Bucket light will remain illuminated and...

Страница 12: ...for continuous drainage Please make sure a water hose rubber washer is used to make a good seal Remove the tank from the front of the unit Open the drain cover on the side of the unit Attach a hose n...

Страница 13: ...let the filter dry before install it NOTE DO NOT rinse or put the filter in an automatic dishwasher DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce perfo...

Страница 14: ...indows and other openings are securely closed Humidity may be entering the room via other sources IE Clothes dryer etc Look for sources of Humidity and correct if necessary Ambient temperature to low...

Страница 15: ...lons Rated Frequency 60 Hz 60 Hz Rated Voltage 115 VAC 115 VAC Rated Current 5 2 A 7 3 A Power Input 615 W 765 W Refrigerant R410A 6 35 OZ QianAn Compressor 7 05 OZ Landa Compressor 9 52 OZ N W 41 8 L...

Страница 16: ...ides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excluded...

Отзывы: