- 7 -
FEATURES
AUTO RESET
When unit is first plugged in or after a power outage, there will be approximately a 2 minute
delay before operation begins. Operation resumes at previous settings.
AUTO SHUT OFF
The water Level Control Switch shuts off the dehumidifier when the tank is full, when the tank is
removed or not replaced in the proper position.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will
continue to run until the frost disappears.
When the coil is defrosted, the compressor or fan will automatically restart and resume operating.
ALARM
If the water tank is full or not installed for more than three minutes, an alarm will beep every 10
seconds to remind you to empty or re-install the tank properly.
The “Full Bucket” light will flash when the water tank is full or improperly installed. In this case, the
water tank should be emptied or re-installed properly.
TIMER
Turns unit off automatically
FAN SELECTION
Select three fan speeds
TANK or CONTINUOUS DRAIN
Select between a drain hose or installed tank to remove moisture.
FILTER ALERT
A light will illuminate alerting you to clean filter.
PROTECTION MONITORING
The unit has diagnostics to prevent damage.