background image

 

- 10 -

 

WATER TANK 

 
 

AUTO SHUT-OFF 

 
When the water tank is full, or when the tank is not properly installed, the “Full Bucket” light will 
illuminate and the unit automatically shuts off. 
Also, when the bucket is out of position, the unit will beep 10 times. The dehumidifier will not 
operate if tank is not in the proper position or the “Full Bucket” light is illuminated. 
 
There are two ways to remove the collected water.   
 

 
USING THE WATER TANK  

 
When the tank is removed the unit will shut off. Empty and replace the water tank into unit. 
If the water tank is not replaced properly the “Full Bucket” light will remain illuminated and the 
unit will not turn on.  
 
IMPORTANT: DO NOT use the hose if using the tank to collect water.  
 

 

 

NOTES:  

 

DO NOT remove the tank while the dehumidifier is operating or if it has just stopped 
operating. This might cause some water to drip to the floor. 

 

Use care removing tank as it can be heavy. Support it with both hands when emptying. 

 

The water tank must be in place and securely seated for the dehumidifier to operate. 

 

Содержание DH450

Страница 1: ...DEHUMIDIFIER USER MANUAL For Models DH450 DH450S DH470 DH470S 950 0141 revA 11 21 11...

Страница 2: ...l but will not affect proper operations and usage Please read carefully the sections corresponding to the specific model you have and keep the manual in a safe place for reference The refrigerant used...

Страница 3: ...icates the possibility of injury or damage to property only WARNING Follow all grounding and electrical requirements as shown on page 4 Turn unit OFF and disconnect power cord from receptacle prior to...

Страница 4: ...place water tank after emptying to prevent water damage to property and unit Do not operate unit with wet hands Close all doors and windows to the room where the dehumidifier is to be operated Dehumid...

Страница 5: ...a dedicated circuit serving only this appliance For your personal safety this appliance must be grounded This appliance has a power supply cord with a grounding plug To minimize possible shock hazard...

Страница 6: ...culation Place the dehumidifier in an area where the temperature will not fall below 41 F 5 C The coils can frost over at temperatures below 41 F which may reduce performance Use the dehumidifier in c...

Страница 7: ...6 OPERATION UNIT OUTLINE NOTE The appearance of the units that you purchased might be slightly different from shown above...

Страница 8: ...l is defrosted the compressor or fan will automatically restart and resume operating ALARM If the water tank is full or not installed for more than three minutes an alarm will beep every 10 seconds to...

Страница 9: ...a hose to drain or until the bucket is full For drier air press the pad and set to a lower percent value For damper air press the pad and set to a higher percent value For the initial use or the humi...

Страница 10: ...gh fan speed which is suitable for maximum dehumidification Medium Press the Fan Speed button until the indicating light for this speed is illuminated The unit will start to operate in Medium fan spee...

Страница 11: ...G THE WATER TANK When the tank is removed the unit will shut off Empty and replace the water tank into unit If the water tank is not replaced properly the Full Bucket light will remain illuminated and...

Страница 12: ...for continuous drainage Please make sure a water hose rubber washer is used to make a good seal Remove the tank from the front of the unit Open the drain cover on the side of the unit Attach a hose n...

Страница 13: ...let the filter dry before install it NOTE DO NOT rinse or put the filter in an automatic dishwasher DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce perfo...

Страница 14: ...indows and other openings are securely closed Humidity may be entering the room via other sources IE Clothes dryer etc Look for sources of Humidity and correct if necessary Ambient temperature to low...

Страница 15: ...lons Rated Frequency 60 Hz 60 Hz Rated Voltage 115 VAC 115 VAC Rated Current 5 2 A 7 3 A Power Input 615 W 765 W Refrigerant R410A 6 35 OZ QianAn Compressor 7 05 OZ Landa Compressor 9 52 OZ N W 41 8 L...

Страница 16: ...ides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excluded...