MULTI-ZONE FEATURES
The Multi-Zone has many sizing options:
Quad Zone Configurations
Dual Zone Configurations
Variable speed inverter type compressors for increased efficiency and quiet operation.
Automatic swing of vertical louvers for improved air flow (up/down).
Manual adjustment of horizontal louvers to set air flow direction (left/right).
Wireless remote control unit.
Comfortable temperature range of 61 ºF to 86 ºF in Cool/Dry/Heat/Fan modes.
TURBO fan mode in Heat and Cool modes for maximum air flow.
Timer mode for automatic starting and/or stopping for a preset period.
SLEEP mode for quiet energy saving operation during sleep periods.
Individual temperature selection for each zone.
MULTI-ZONE OPERATION
The Multi-Zone mini-split will operate each zone in either cooling or heating mode but not both. The unit will
not operate as one zone cool and another heat. If this occurs, an E7 error will be displayed. To clear this
error, make sure all indoor units are in the same mode either heat or cool. Each zone will control the room
temperature at set-point and allow all normal fan, swing, turbo, timer, and sleep functions
.
Emergency Operation (Auto/Stop Switch)
In the event that the remote controls are misplaced, you can operate your
inside unit by carefully raising the cover and pressing the emergency
operation switch located under the lower right hand corner of the cover.
To open the front cover, place fingers in the bottom of the slots on the side of
the indoor unit and gently pull outward. To close the cover, press down on each end and center of
the cover to latch.
2 INDOOR UNITS
3 INDOOR UNITS
4 INDOOR UNITS
9K + 9K
9K + 12K
12K + 12K
9K + 18K
12K + 18K
9K + 9K + 9K
9K + 9K + 12K
9K + 12K + 12K
9K + 9K + 18K
9K + 9K + 9K + 9K
The system matches below are not
recommended if all indoor units may
require simultaneous continuous duty
at full efficiency.
The system matches below are not
recommended if all indoor units may
require simultaneous continuous duty
at full efficiency.
The system matches below are not
recommended if all indoor units may
require simultaneous continuous duty
at full efficiency.
18K + 18K
9K + 12K + 18K
12K +12K + 12K
12K + 12K + 18K
9K + 9K + 9K + 12K
9K + 9K + 9K + 18K
9K + 9K + 12K + 12K
2 INDOOR UNITS
9K + 9K
9K + 12K
12K + 12K
Indoor Models Available:
9K Indoor
– MZG409HP16230EA, 9MH46ZIGX
12K Indoor
– MZG412HP16230EA, 12MH46ZIGX
18K Indoor - MZG418HP16230EA, 18MH46ZIGX