background image

950-0154revD                                                          - 12 -                                                                       April 19, 2012 

Malfunction Name 

Display 

Running 

LED 

Heating 

LED 

Cooling 

LED 

System Overload 

H4 

 

4 Flashes  

 

Compressor Overload Protection 

H3 

 

3 Flashes 

 

IPM Protection 

H5 

 

5 Flashes 

 

Condenser Fan Motor Error 

L3 

 

 

 

High Pressure Protection 

E1 

1 Flash 

 

 

Anti-Freezing Protection 

E2 

2 Flashes 

 

 

Exhaust Protection (Temperature) 

E4 

4 Flashes 

 

 

Over Current Protection 

E5 

5 Flashes 

 

 

Mode Conflict 

E7 

7 Flashes 

 

 

Communication Malfunction 

E6 

6 Flashes 

 

 

Defrost or Oil Return Heat Mode 

H1 

 

1 Flash 

 

Indoor Ambient Sensor Malfunction 

F1 

 

 

1 Flash 

Indoor Tube Sensor Malfunction 

F2 

 

 

2 Flashes 

Outdoor Ambient Sensor Malfunction 

F3 

 

 

3 Flashes 

Outdoor Tube Sensor Malfunction 

F4 

 

 

4 Flashes 

Outdoor Exhaust Sensor Malfunction 

F5 

 

 

5 Flashes  

Startup Failure 

H7 

 

7 Flashes  

 

PFC Malfunction  

HC 

 

6 Flashes 

 

Demagnetizing Protection for Compressor 

HE 

 

14 Flashes 

 

Zero Crossing Detector 

U9 

 

 

 

 

Frequency Drop for Overload 

F6 

 

 

6 Flashes 

Frequency Drop for Over Current Protection 

F8 

 

 

8 Flashes 

Frequency Drop for Exhaust Protection 

F9 

 

 

9 Flashes 

Frequency Drop for Heating High 

Temperature  Protection 

H0 

 

10 Flashes  

 

Anti-Cold Protection 

E9 

9 Flashes 

 

 

Oil Return in Cooling Mode 

F7 

 

 

7 Flashes 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 12MH46ZIGX

Страница 1: ...HIGH EFFICIENCY SERIES OPERATION MANUAL SINGLE ZONE MODELS DUAL ZONE MODELS TRI QUAD ZONE MODELS 950 0154revD April 19 2012...

Страница 2: ...al Support Warranty 13 HIGH EFFICIENCY SERIES SINGLE ZONE MODELS Thermal Zone Cool Only Sea Breeze Cool Only SEER RATING MS49A23115EA 9A423YIGX 23 SEER MS412A22115EA 12A422YIGX 22 SEER MS412A22230EA 1...

Страница 3: ...means of turning the unit on or off except in the case of an emergency Do not operate this unit if you are wet or have wet hands electric shock can occur Do not spray insecticides paints or other fla...

Страница 4: ...il 19 2012 PARTS IDENTIFICATION Indoor Unit Air In Front Cover Filter Louvers Air Out Line set Collar Binding Tape Remote Control Wiring and Copper Tube Drain Tube COOL HEAT FAN DRY PURGE DISPLAY TIME...

Страница 5: ...nt and allow all normal fan swing turbo timer and sleep functions Emergency Operation Auto Stop Switch In the event that the remote controls are misplaced you can operate your inside unit by carefully...

Страница 6: ...temperature goes above 77 F unit switches to COOL mode If temperature is in between 68 F to 77 F the unit runs in the FAN mode Notes 1 Indoor fan does not turn off in the cooling mode when temperature...

Страница 7: ...it automatically switches between HEAT COOL or FAN If other zones are set to HEAT or COOL while the AUTO is running in an opposite mode an E7 will occur To rectify this condition you must set all the...

Страница 8: ...the set point it gets On the other hand the closer it gets to the set point the slower it will run CLOCK Press the CLOCK button the clock ICON will start to blink It will only blink for 5 seconds Whil...

Страница 9: ...eable batteries If the wireless remote control will not be used for a long period of time remove the batteries If the wireless remote control does not operate properly remove the batteries for 30 seco...

Страница 10: ...r and dry it in the shade NOTE Do not use water above 113 F to wash filter it can deform the filter Reinstall the filters and close the cover Turn power on unit is ready for use NEVER OPERATE THE UNIT...

Страница 11: ...into room The air humidity is excessively high Check to see if all windows and doors are closed Call service Tech if not corrected by the above action Water leakage in outdoor unit When the unit is r...

Страница 12: ...e H1 1 Flash Indoor Ambient Sensor Malfunction F1 1 Flash Indoor Tube Sensor Malfunction F2 2 Flashes Outdoor Ambient Sensor Malfunction F3 3 Flashes Outdoor Tube Sensor Malfunction F4 4 Flashes Outdo...

Страница 13: ...OES NOT cover Damage accidental or otherwise to the unit while in possession of the consumer that is not a result of a defect in material in workmanship Damage caused by consumer misuse tampering or f...

Отзывы: