441 01 2613 05
3
Specifications are subject to change without notice
1. Safe Installation Requirements
FIRE, EXPLOSION, AND ASPHIXIATION HAZARD
Improper adjustment, alteration, service,
maintance or installation could cause personal
injury, death, and/or property damage.
Installation or repairs made by unqualified persons
could result in hazards to you and others.
Installation MUST conform with local codes or, in
the absence of local codes, with codes of all
governmental authorities having jurisdiction.
The information contained in this manual is
intended for use by a qualified service agency that
is experienced in such work, is familiar with all
precautions and safety procedures required in
such work, and is equipped with the proper tools
and test instruments.
!
WARNING
NOTE
: This furnace is design
!
certified by the CSA International
(formerly AGA and CGA) for installation in the United States and
Canada. Refer to the appropriate codes, along with this manual,
for proper installation.
•
Use only the Type of gas approved for this furnace (see
Rating Plate
on unit). Overfiring will result in failure of heat
exchanger and cause dangerous operation. (Furnaces
can be converted to Propane gas with approved kit.)
•
Install this furnace only in a location and position as
specified in “
Installation”
of these instructions.
•
Provide adequate combustion and ventilation air to the
furnace as specified in “
Combustion and Ventilation Air”
of
these instructions.
•
Combustion products must be discharged outdoors.
Connect this furnace to an approved vent system only, as
specified in “
Gas Vent Installation, Horizontal Venting and
Masonry Chimney Venting”
of these instructions.
•
Never test for gas leaks with an open flame. Use a
commercially available soap solution made specifically for
the detection of leaks to check all connections, as
specified in “
Gas Supply and Piping, Final Check”
of these
instructions.
•
Always install furnace to operate within the furnace’s
intended temperature
!
rise range with a duct system which
has an external static pressure within the allowable range,
as specified in “
Technical Support Manual”
of these
instructions. See furnace rating plate.
•
When a furnace is installed so that supply ducts carry air
circulated by the furnace to areas outside the space
containing the furnace, the return air shall also be handled
by a duct(s) sealed to the furnace casing and terminating
outside the space containing the furnace.
•
A gas
!
fired furnace for installation in a residential garage
must be installed as specified in “
Installation”
of these
instructions.
•
This furnace is not to be used for temporary heating of
buildings or structures under construction.
•
This furnace is NOT approved for installation in
mobile homes, trailers or recreation vehicles.
•
Seal around supply and return air ducts.
•
Install correct filter type and size.
•
Unit
MUST
be installed so electrical components are
protected from direct contact with water.
Safety Rules
Your unit is built to provide many years of safe and dependable
service providing it is properly installed and maintained. However,
abuse and/or improper use can shorten the life of the unit and
create hazards for you, the owner.
A. The U.S. Consumer Product Safety Commission encourages
installation of carbon monoxide alarms. There can be various
sources of carbon monoxide in a building or dwelling. The
sources could be gas
!
fired clothes dryers, gas cooking
stoves, water heaters, furnaces, gas
!
fired fireplaces, wood
fireplaces.
Carbon monoxide can cause serious bodily injury and/or
death. Carbon monoxide or “CO” is a colorless and odorless
gas produced when fuel is not burned completely or when the
flame does not receive sufficient oxygen.
Therefore, to help alert people of potentially dangerous carbon
monoxide levels, you should have a commercially available
carbon monoxide alarm that is listed by a nationally
recognized testing agency in accordance with Underwriters
Laboratories Inc. Standard for Single and Multiple Station
Carbon Monoxide Alarms, ANSI/UL 2034 or the CSA 6.19
!
01
Residential Carbon Alarming Devices installed and
maintained in the building or dwelling concurrently with the
gas
!
fired furnace installation (see Note below). The alarm
should be installed as recommended by the alarm
manufacturer’s installation instructions.
B. There can be numerous sources of fire or smoke in a building
or dwelling. Fire or smoke can cause serious bodily injury,
death, and/or property damage. Therefore, in order to alert
people of potentially dangerous fire or smoke, you should have
fire extinguisher and smoke alarms listed by Underwriters
Laboratories installed and maintained in the building or
dwelling (see Note below).
Note:
The manufacturer of your furnace does not test any alarms
and makes no representations regarding any brand or type
of alarms.
C. To ensure safe and efficient operation of your unit, you should
do the following:
1.
Thoroughly read this manual and labels on the unit.
This
will help you understand how your unit operates and the
hazards involved with gas and electricity.
2.
Do not use this unit if any part has been under water.
Immediately call a qualified service agency to inspect the unit
and to replace any part of the control system and any gas
control which has been under water.
3.
Never obstruct the vent grilles, or any ducts that provide
air to the unit.
Air must be provided for proper combustion and
ventilation of flue gases.
Frozen Water Pipe Hazard
WATER DAMAGE TO PROPERTY HAZARD
FaiIure to follow this warning could result in
property damage.
Do not leave your home unattended for long periods
during freezing weather without turning off water
supply and draining water pipes or otherwise
protecting against the risk of frozen pipes and
resultant damage.
!
WARNING
National Excelsior Company
www.excelsiorhvac.com
Subject to change without notice.