Your responsibilities as an equipment owner  

 

Your  Patriot  Twin  Analyst  System  is  manufactured  to  be  efficient  and  reliable.  To  ensure  continued  perfor-
mance while keeping your system operating within manufacturer’s specifications, the following operating con-
ditions must be ensured by you, the equipment owner/operator:  
 
 

Water Pressure Regulator 

 

The influent water pressure into this water system must be regulated by a code-compliant pressure-regulating 
device not to exceed 75psi.  
 

Power Protection 

 

Power to this system must be supplied by an unswitched 110VAC supply. Surge protection is mandatory and is 
to be supplied by you, the equipment owner. The use of a UPS (Uninterruptible Power Supply) is encouraged.  
 

Salt 

 

This water system uses either sodium or potassium salt to clean itself. The brine tank must be filled with a high 
quality pellet or cubed salt to ensure system operation. Rock salt is usually not suitable for this system, as it can 
contain higher levels of impurities that can require more frequent disinfection and can possibly even compro-
mise system functionality. Consult with your local water professional to decide on the best salt for your applica-
tion. 
 

Pur-Gard 

 

The Pur-Gard injection feeder should be kept full to ensure proper system operation and maximum efficiency. 
Pur-Gard works synergistically with the water softening media to ensure the very best water quality and to max-
imize cleaning power. Check the level of your Pur-Gard feeder each time you fill your brine tank with salt.  
 

Annual Cleaning and Disinfection 

Bacteria  can  colonize water softeners through safe city water, salt, or  even ambient  air. Weekly  antibacterial 
rinses and supplementation with Pur-Gard help minimize bacterial growth, your system should be cleaned and 
disinfected on a regular schedule to ensure peak performance and protect the safety of you family. Your local 
dealer can perform the cleaning and disinfection service for you, or you can purchase a comprehensive cleaning 
and disinfection kit to perform this task yourself.   
 

Periodic replacement of media 

While built to the highest standards, certain media in your Patriot Twin Analyst System will need to be replaced 
periodically by your local authorized service agent. Replacement intervals vary depending on your water chem-
istry and water consumption habits. Consult with your water specialist during  your annual inspection/tune-up 
service to ensure that you enjoy the very best water quality. 

 

Содержание Patriot Twin Analyst

Страница 1: ...Patriot Twin Analyst Owner s Manual Owner s Manual Revision 1 1 Page 1 Owner s Manual Patriot Twin Analyst...

Страница 2: ...asteless and can sometimes be life threatening The state ment my parents drank this water for 75 years and it never hurt them is no longer a valid excuse to not be concerned with water quality There h...

Страница 3: ...here are several degrees of water hardness Even moderately hard water can seriously damage the plumbing system in your home and in time cause inconvenient and expensive problems Hard water is a poor c...

Страница 4: ...ard water affects your house plumbing Perhaps the greatest damage done by hard water is the damage that you can t easily see Water heaters hu midifiers boilers and household pipes become lined with an...

Страница 5: ...INE Increased Water Heating Costs Damaged Clothing Excessive Soap Consumption Pipe Scaling Faucet and Fixture Damage Skin Problems Unpalatable Food Undesirable Tastes and Odors Premature Appliance Fai...

Страница 6: ...control center can be up dated with the latest software updates upgrades as they become available Reliable The mechanical subsystem in the Patriot Twin Analyst System is revolutionary in its own right...

Страница 7: ...ith your local water professional to decide on the best salt for your applica tion Pur Gard The Pur Gard injection feeder should be kept full to ensure proper system operation and maximum efficiency P...

Страница 8: ...unts of Pur Gard depending on your water consump tion habits always maximizing efficiency and performance while providing you with the water quality that you deserve Pur Gard is designed to Clean ion...

Страница 9: ...gus that can enter the system through safe city water salt or even from the air These additional contam inants slowly accumulate in your softener and can even colonize it with a biofilm of Heterotroph...

Страница 10: ...ping handling Allow water to run until clear Observe water for particles If resin particles are found in the water bypass the sys tem and call tech support Leave the bathtub running Program the system...

Страница 11: ...Patriot Twin Analyst Owner s Manual Owner s Manual Revision 1 1 Page 11...

Страница 12: ...ogramming to indicate if the displayed parameter is locked icon flashes when controller is in Level I 10 When x2 is displayed a second regeneration has been scheduled 11 Recycle icon displayed flashin...

Страница 13: ...g Mode In deep cleaning mode the display shows the current cleaning cycle step and the remaining time for that cycle to execute Flow meter In service mode the display will show the time of day and rem...

Страница 14: ...RA CYCLE Used to instruct the controller to regenerate Time of Day Set the current time of day Hardness Set the compensated hardness level A compensated hardness level is the amount of actual calcium...

Страница 15: ...essing SET for 3 seconds at H0 will reset control to factory defaults Delayed Manual Regeneration Press and release the REGENERATE button Press REGENERATE button again to cancel Immediate Manual Regen...

Страница 16: ...104 m3 H7 Average usage for Sunday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 H8 Average usage for Monday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 H9 Average usage for Tuesday in...

Страница 17: ...f hardness and other contaminants before becoming exhausted This is referred to as the capacity of the resin The capacity of the resin is referred to as grains of cal cium carbonate hardness removed p...

Страница 18: ...n it should clean itself using the latest algo rithms that consider your water usage habits water hardness and the status of its resin exhaustion sensors Your system will periodically perform an antib...

Страница 19: ...the media bed and out of tank to drain Tank Fill Your system will add the prescribed amount of water to the salt tank compressing the media bed and preparing it for ser vice Brine Draw Your system wi...

Страница 20: ...fer to problem System fails to clean Valve fails to draw brine Refer to problem Valve fails to draw brine Decreasing exchange capacity of resin Clean or replace resin bed No salt in brine tank Add sal...

Страница 21: ...ctions Restricted Obstructed brine line Check brine line for kinks restrictions or obstructions Leak in brine line Verify brine line and connections for air leakage Insufficient water in brine tank Re...

Страница 22: ...brine tank Unit regenerates too frequently Check household for excessive or unexpected water usage leaky toilet fill valves T P Relief drainage Reverse Osmosis processors humidifiers plumbing leaks et...

Страница 23: ...ropriate remedial action Cause Solution Mineral or iron build up in resin tank Clean resin bed and control valve increase regeneration frequency Increase Pur Gard dosage rate Plugged lower and or uppe...

Страница 24: ...se required by applicable law Intermountain Soft Water shall not be liable for any damages whatsoever including without limitation loss time inconvenience expenses such as telephone calls labor or mat...