Patriot Twin Analyst – Owner’s Manual – Revision 1.1 

Page 12 

Understanding Your Controller 

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Selected when programming the maximum interval between antibacterial cycles. 
2.  This icon identifies the day of the week. 
3.  "PM" indicates that the time displayed is between 12:00 noon and 12:00 midnight (there is no AM in-

dicator). PM indicator is not used if clock mode is set to 24-hour format. 

4.  When "MIN" is displayed, the value entered is in minute increments. 
5.  When g/L is displayed, the value for regenerant amount entered is in grams/Liter of resin. 
6.  When "Kg" is displayed, the value entered is in kilograms or kilograins. 
7.  Four digits used to display the time or program value. Also used for error codes. 
8.  Colon used as part of the time display. 
9.  Locked/unlocked  indicator.  In  Level  I  Programming  this  is  displayed  when  the  current  parameter  is 

locked-out.  It  is  also  used  in  Level  II  Programming  to  indicate  if  the  displayed  parameter  is  locked 
(icon flashes) when controller is in Level I. 

10. When "x2" is displayed, a second regeneration has been scheduled. 
11. Recycle icon, displayed (flashing) when a regeneration cycle has been scheduled, or (solid) when the 

system is cleaning itself. 

12. Selected when programming the amount of regenerant. 
13. Selected when programming regeneration day and time functions. 
14. Selected when programming the current time and day. 
15. The hourglass is displayed when the motor is running. The camshaft should be turning. 
16. These cursors appear next to the item that is currently displayed. 
17. x100 multiplier for large numerical values. 
18. value for regenerant amount entered is in pounds/cubic foot of resin. 
19. Faucet is displayed when the current flow rate is displayed on the numeric display. 
20. On when preventative scheduled maintenance is needed. 
21. Displays the tank in service during normal operating mode 
22. History Values (H).  
23. Parameter (P). 
24. Cycle (C).  
25. Hardness setting. 
26. Capacity display—shows estimated system capacity remaining. 

Содержание Patriot Twin Analyst

Страница 1: ...Patriot Twin Analyst Owner s Manual Owner s Manual Revision 1 1 Page 1 Owner s Manual Patriot Twin Analyst...

Страница 2: ...asteless and can sometimes be life threatening The state ment my parents drank this water for 75 years and it never hurt them is no longer a valid excuse to not be concerned with water quality There h...

Страница 3: ...here are several degrees of water hardness Even moderately hard water can seriously damage the plumbing system in your home and in time cause inconvenient and expensive problems Hard water is a poor c...

Страница 4: ...ard water affects your house plumbing Perhaps the greatest damage done by hard water is the damage that you can t easily see Water heaters hu midifiers boilers and household pipes become lined with an...

Страница 5: ...INE Increased Water Heating Costs Damaged Clothing Excessive Soap Consumption Pipe Scaling Faucet and Fixture Damage Skin Problems Unpalatable Food Undesirable Tastes and Odors Premature Appliance Fai...

Страница 6: ...control center can be up dated with the latest software updates upgrades as they become available Reliable The mechanical subsystem in the Patriot Twin Analyst System is revolutionary in its own right...

Страница 7: ...ith your local water professional to decide on the best salt for your applica tion Pur Gard The Pur Gard injection feeder should be kept full to ensure proper system operation and maximum efficiency P...

Страница 8: ...unts of Pur Gard depending on your water consump tion habits always maximizing efficiency and performance while providing you with the water quality that you deserve Pur Gard is designed to Clean ion...

Страница 9: ...gus that can enter the system through safe city water salt or even from the air These additional contam inants slowly accumulate in your softener and can even colonize it with a biofilm of Heterotroph...

Страница 10: ...ping handling Allow water to run until clear Observe water for particles If resin particles are found in the water bypass the sys tem and call tech support Leave the bathtub running Program the system...

Страница 11: ...Patriot Twin Analyst Owner s Manual Owner s Manual Revision 1 1 Page 11...

Страница 12: ...ogramming to indicate if the displayed parameter is locked icon flashes when controller is in Level I 10 When x2 is displayed a second regeneration has been scheduled 11 Recycle icon displayed flashin...

Страница 13: ...g Mode In deep cleaning mode the display shows the current cleaning cycle step and the remaining time for that cycle to execute Flow meter In service mode the display will show the time of day and rem...

Страница 14: ...RA CYCLE Used to instruct the controller to regenerate Time of Day Set the current time of day Hardness Set the compensated hardness level A compensated hardness level is the amount of actual calcium...

Страница 15: ...essing SET for 3 seconds at H0 will reset control to factory defaults Delayed Manual Regeneration Press and release the REGENERATE button Press REGENERATE button again to cancel Immediate Manual Regen...

Страница 16: ...104 m3 H7 Average usage for Sunday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 H8 Average usage for Monday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 H9 Average usage for Tuesday in...

Страница 17: ...f hardness and other contaminants before becoming exhausted This is referred to as the capacity of the resin The capacity of the resin is referred to as grains of cal cium carbonate hardness removed p...

Страница 18: ...n it should clean itself using the latest algo rithms that consider your water usage habits water hardness and the status of its resin exhaustion sensors Your system will periodically perform an antib...

Страница 19: ...the media bed and out of tank to drain Tank Fill Your system will add the prescribed amount of water to the salt tank compressing the media bed and preparing it for ser vice Brine Draw Your system wi...

Страница 20: ...fer to problem System fails to clean Valve fails to draw brine Refer to problem Valve fails to draw brine Decreasing exchange capacity of resin Clean or replace resin bed No salt in brine tank Add sal...

Страница 21: ...ctions Restricted Obstructed brine line Check brine line for kinks restrictions or obstructions Leak in brine line Verify brine line and connections for air leakage Insufficient water in brine tank Re...

Страница 22: ...brine tank Unit regenerates too frequently Check household for excessive or unexpected water usage leaky toilet fill valves T P Relief drainage Reverse Osmosis processors humidifiers plumbing leaks et...

Страница 23: ...ropriate remedial action Cause Solution Mineral or iron build up in resin tank Clean resin bed and control valve increase regeneration frequency Increase Pur Gard dosage rate Plugged lower and or uppe...

Страница 24: ...se required by applicable law Intermountain Soft Water shall not be liable for any damages whatsoever including without limitation loss time inconvenience expenses such as telephone calls labor or mat...

Отзывы: