1. With the POWER switch OFF, plug the supply power cord into an appropriate,
grounded, receptacle. (refer to the cabinet data plate for voltage and
ampere rating).
2. Ensure that the cabinet’s floor duct and water pan are installed. (refer to the cabinet
operating instructions). This helps to distribute the heat evenly throughout the cabinet.
3. If extra humidity is desired, fill the water pan in the floor duct of the cabinet with clean
warm water. The capacity of the reservoir is about one quart (one liter).
4. Set the POWER switch to the ON position.
5. The cabinet will initially display the current temperature set point and then show the
actual cabinet temperature.
6. The temperature display will continue to blink until the temperature set point
is reached.
7. To change temperature set point, turn the control knob. As the knob is turned, the
temperature display will show the changing temperature set point, and the “°F and
°C” indicator lamps will blink. About 3 seconds after the knob is turned, the display will
show the actual cabinet temperature.
8. Press and release “Recall Set Points” button to see the current temperature set point.
9. To see the current low temperature alarm set point, press and release the “Low
Temp Alarm” button. To change the low temperature alarm set point, press and hold
the “Low Temp Alarm” button, turn the temperature knob to the desired setting, and
release the button.
10. To clean cabinet, turn power off, unplug from wall outlet, allow the cabinet to cool,
remove the floor duct and pan, wipe the cabinet with a damp cloth and
dry with a towel.