background image

7

PRODUCT FEATURES

Field Reversible 

Doors 

Be careful when 

opening the doors 

as hot, humid air will 

escape the cabinet.

Tray Slides

Floor Duct 

Holds water 

pan and evenly 

distributes air flow.

Water Pan

Fill with water. 

Capacity is 

1 quart (1 liter).

Air Duct

Flush Pull Handles

Control Panel

Temperature Control 

Controls the temperature in the cabinet. 

Turn the knob to change the temperature 

set point. The display shows new set 

point as the knob is turned.

Power Switch

Low Temperature Alarm 

Sets and recalls the low 

temperature alarm set point.

Element Cycling 

Indicator Light 

Indicates air heat 

element is on.

Set Point Recall 

Displays cabinet’s 

temperature set point.

Temperature Scale Indicators 

Set to Fahrenheit in the factory. 

These indicators will also blink 

while the temperature set point 

is being displayed. 

Air Temperature Display 

Displays the current cabinet 

temperature. Also displays low 

temperature warning.

Audio Disable (Sound Off) 

Press “Recall Set Points” and “Low 

Temp Alarm”  buttons simultaneously 

and hold for five seconds to toggle 

sound off and on.

Содержание METRO C5 8 Series

Страница 1: ...o Heated Cabinets are for Hot Food Holding applications only This manual covers cabinets with electrical ratings of 120V 2000W 120V 1440W 220 240V 1681 2000W When ordering electrical parts always conf...

Страница 2: ...perature set point is reached 7 To change temperature set point turn the control knob As the knob is turned the temperature display will show the changing temperature set point and the F and C indicat...

Страница 3: ...g placed into this cabinet Use a food probe to check internal food temperature the cabinet temperature is not necessarily the internal food temperature WARNING Only factory approved service agents sho...

Страница 4: ...E 8 8 SERIES CONTROLLED TEMPERATURE CABINET SIZE HEIGHT 9 FULL 7 3 4 5 1 2 3 UNDER COUNTER MATERIAL S STAINLESS N ALUMINUM A ACCESSORIES IF APPLICABLE ELECTRICAL CABINET RATING BLANK 120V 2000W L 120V...

Страница 5: ...ground wire connection and the wire nuts on the black and white wires have not loosened Do not alter the wiring of the power cord to the cabinet Replace the cabinet top and the 7 screws holding it in...

Страница 6: ...uprights includes slides and uprights includes slides and uprights SLIDE INSTALLATION The rack uprights have been installed at the factory If removed for cleaning reinstall by hanging them on the shou...

Страница 7: ...r Counter Single Door Dutch Doors Cabinet Cabinet Cabinet 2 piece Construction 2 piece Construction 1 piece Construction 1 piece Construction 1 piece Construction Part No RPC5 L9 Part No RPC5 L9 Part...

Страница 8: ...w the top and install the hinges On Dutch Doors do not remove the handles the top door becomes the bottom and the bottom door the top On single door units rotate the handles 180 and reinstall 4 On the...

Страница 9: ...as the knob is turned Power Switch Low Temperature Alarm Sets and recalls the low temperature alarm set point Element Cycling Indicator Light Indicates air heat element is on Set Point Recall Displays...

Страница 10: ...operation unless the low temperature alarm has been disabled see below The TEMPERATURE display will begin to blink L0 alternating with the current temperature An audible alarm will also sound 3 times...

Страница 11: ...nt Indicator Water Pan Fill with water Capacity is about 1 quart 1 liter CARE MAINTENANCE Cleaning The Cabinet Warning Unplug the cabinet before cleaning or servicing Do not wash the cabinet with a wa...

Страница 12: ...rculating air i Blower wiring is faulty or disconnected ii Blower needs replacing 5 No heat generated a If the heat indicator light is on but the cabinet does not draw approximately 16 amps for 120V 2...

Страница 13: ...2103 BLOWER 120V 6 RPC13 093 ELEMENT 120V 1950W 6A RPC13 114 ELEMENT 120V 1360W 7 RPC13 198 THERMAL CUT OUT 8 RPC13 359 POWER CORD 20A RT ANGLE PLUG RPC13 099 POWER CORD 20A STR PLUG RPC5 RTWSTPLG PO...

Страница 14: ...R HINGE 1 PIECE 17 B5DNB 5 BRAKE CASTER B3B 3 BRAKE CASTER RPQC02 248 6 BRAKE CASTER 18 B5DN 5 SWIVEL CASTER B3 3 SWIVEL CASTER B5DRN 5 RIGID CASTER RPQC02 247 6 SWIVEL CASTER 19 RPC11 481 WATER PAN 2...

Страница 15: ...ed Replacement Parts Diagram For slide identification see pages 4 and 5 STRAIGHT PLUG CORD SHOWN 24 14 25 18 15 22 20 23 CABINET BODY 8 9 10 11 21 13 19 CONTROL PANEL See page 11 FLOOR DUCT 17 16 AIR...

Страница 16: ...16 21 15 24 18 20 14 19 13 11 10 9 12 8 7 5 4 3 6 2 1 19 BLACK X 15 RING TO SPADE 17 22 BLACK X 15 RING TO SPADE 21 21 10 WHITE X 30 BLACK X 30 WHITE X 24 BLACK X 30 BLACK X 30 BLOWER AIR ELEMENT BLAC...

Страница 17: ...InterMetro Industries Corporation hereinafter referred to as Seller warrants to the 10 17 15...

Страница 18: ...elect Online Warranty Registration to register electronically FOLD HERE DO NOT DETACH 16 CUSTOMER INFORMATION 1 Which one of the following best describes your establishment a Full Service Restaurant b...

Страница 19: ...WILL BE PAID BY INTERMETRO INDUSTRIES CORPORATION ATTN CUSTOMER SERVICE P O BOX A WILKES BARRE PA 18705 9968 STAPLE HERE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL F I R S...

Страница 20: ...THIS PAGE IS KEPT INTENTIONALLY BLANK...

Страница 21: ...h Washington Street Wilkes Barre PA 18705 For Product Information Call 1 800 992 1776 Visit Our Web Site www metro com L01 425 Rev G 10 17 Information and specifications are subject to change without...

Отзывы: