InterMetro Ind. METRO C5 8 Series Скачать руководство пользователя страница 13

11

6 OR 6A 

7

5

AIR DUCT

COVER

4

AIR DUCT

AIR DUCT

SERVICE and REPLACEMENT PARTS

C5 8 SERIES REPLACEMENT PARTS — ELECTRICAL

Confirm the cabinet electrical rating before ordering components.

Warning: 

Only factory approved service agents should attempt to service, repair or replace electrical components, 

wiring or power cord.

To access the controller area, remove the (7) screws holding the cabinet top in place. Lift the rear portion of the 

cabinet top and slide it away from under the front control bezel, removing it from the cabinet. After servicing, replace 

the cabinet top and the (7) screws holding it in place. 

  

120V 1440W OR 2000W

 

ITEM #  Replacement Part No.  Description 

  1 

RPC5-8CONTR 

120V (°F) CONTROLLER, 

SENSORS & WIRING

  2  

RPC13-375 

MASTER SWITCH

  3 

RPC5-KNOB 

CONTROLLER KNOB

  4 

RPC11-191 

INTAKE COLLAR

  5 

RPHM20-2103 

BLOWER, 

120V

  6

 RPC13-093 

ELEMENT, 

120V 1950W

  6A 

RPC13-114 ELEMENT, 

120V 1360W

  7 

RPC13-198 

THERMAL CUT OUT

  8 

RPC13-359 

POWER CORD, 

20A RT 

ANGLE PLUG

 

RPC13-099 

POWER CORD, 

20A STR PLUG

 

RPC5-RTWSTPLG  POWER CORD, 

20A TWIST 

LK PLUG

 8A 

RPC13-348 

POWER CORD, 

15A RT 

ANGLE PLUG

 

RPC13-289 

POWER CORD, 

15A STR PLUG

 

RPC13-337 

POWER CORD, 

15A TWIST 

LK PLUG

 9

 

RPC13-098 

STRAIN RELIEF, 

20A CORD

 9A

  RPC13-083 

STRAIN RELIEF, 

15A CORD

 10

 

RPC13-096 

TERMINAL BLOCK 

 11

 

RPC07-055 

SENSOR CABLE GROMMET 

 12

 

RPC5-SCLP 

SENSOR CLAMP & SCREW 

 28

 RPC5-5VFAN 

FAN, 

5V

 

220-240V 1681W OR 2000W

 

ITEM #  Replacement Part No.  Description 

  1 

RPC5X-8CONTR 

220-240V (°C) CONTROLLER, 

SENSORS & WIRING 

  2 

RPC13-375 

MASTER SWITCH

  3 

RPC5-KNOB 

CONTROLLER KNOB

  4 

RPC11-191 

INTAKE COLLAR

  5 

RPHX20-2103 

BLOWER, 

220V-240V

  6

 RPC13-117 

ELEMENT, 

240V 1950W

 

  7 

RPC13-198 

THERMAL CUT OUT

  8 

RPC13-247 

POWER CORD, 

250V 15A

  9

 

RPC13-083 

STRAIN RELIEF, 

15A CORD

 10

 

RPC13-096 

TERMINAL BLOCK 

 11

 

RPC07-055 

SENSOR CABLE GROMMET 

 12

 

RPC5-SCLP 

SENSOR CLAMP & SCREW

 28

 RPC5-5VFAN 

FAN, 

5V 

Содержание METRO C5 8 Series

Страница 1: ...o Heated Cabinets are for Hot Food Holding applications only This manual covers cabinets with electrical ratings of 120V 2000W 120V 1440W 220 240V 1681 2000W When ordering electrical parts always conf...

Страница 2: ...perature set point is reached 7 To change temperature set point turn the control knob As the knob is turned the temperature display will show the changing temperature set point and the F and C indicat...

Страница 3: ...g placed into this cabinet Use a food probe to check internal food temperature the cabinet temperature is not necessarily the internal food temperature WARNING Only factory approved service agents sho...

Страница 4: ...E 8 8 SERIES CONTROLLED TEMPERATURE CABINET SIZE HEIGHT 9 FULL 7 3 4 5 1 2 3 UNDER COUNTER MATERIAL S STAINLESS N ALUMINUM A ACCESSORIES IF APPLICABLE ELECTRICAL CABINET RATING BLANK 120V 2000W L 120V...

Страница 5: ...ground wire connection and the wire nuts on the black and white wires have not loosened Do not alter the wiring of the power cord to the cabinet Replace the cabinet top and the 7 screws holding it in...

Страница 6: ...uprights includes slides and uprights includes slides and uprights SLIDE INSTALLATION The rack uprights have been installed at the factory If removed for cleaning reinstall by hanging them on the shou...

Страница 7: ...r Counter Single Door Dutch Doors Cabinet Cabinet Cabinet 2 piece Construction 2 piece Construction 1 piece Construction 1 piece Construction 1 piece Construction Part No RPC5 L9 Part No RPC5 L9 Part...

Страница 8: ...w the top and install the hinges On Dutch Doors do not remove the handles the top door becomes the bottom and the bottom door the top On single door units rotate the handles 180 and reinstall 4 On the...

Страница 9: ...as the knob is turned Power Switch Low Temperature Alarm Sets and recalls the low temperature alarm set point Element Cycling Indicator Light Indicates air heat element is on Set Point Recall Displays...

Страница 10: ...operation unless the low temperature alarm has been disabled see below The TEMPERATURE display will begin to blink L0 alternating with the current temperature An audible alarm will also sound 3 times...

Страница 11: ...nt Indicator Water Pan Fill with water Capacity is about 1 quart 1 liter CARE MAINTENANCE Cleaning The Cabinet Warning Unplug the cabinet before cleaning or servicing Do not wash the cabinet with a wa...

Страница 12: ...rculating air i Blower wiring is faulty or disconnected ii Blower needs replacing 5 No heat generated a If the heat indicator light is on but the cabinet does not draw approximately 16 amps for 120V 2...

Страница 13: ...2103 BLOWER 120V 6 RPC13 093 ELEMENT 120V 1950W 6A RPC13 114 ELEMENT 120V 1360W 7 RPC13 198 THERMAL CUT OUT 8 RPC13 359 POWER CORD 20A RT ANGLE PLUG RPC13 099 POWER CORD 20A STR PLUG RPC5 RTWSTPLG PO...

Страница 14: ...R HINGE 1 PIECE 17 B5DNB 5 BRAKE CASTER B3B 3 BRAKE CASTER RPQC02 248 6 BRAKE CASTER 18 B5DN 5 SWIVEL CASTER B3 3 SWIVEL CASTER B5DRN 5 RIGID CASTER RPQC02 247 6 SWIVEL CASTER 19 RPC11 481 WATER PAN 2...

Страница 15: ...ed Replacement Parts Diagram For slide identification see pages 4 and 5 STRAIGHT PLUG CORD SHOWN 24 14 25 18 15 22 20 23 CABINET BODY 8 9 10 11 21 13 19 CONTROL PANEL See page 11 FLOOR DUCT 17 16 AIR...

Страница 16: ...16 21 15 24 18 20 14 19 13 11 10 9 12 8 7 5 4 3 6 2 1 19 BLACK X 15 RING TO SPADE 17 22 BLACK X 15 RING TO SPADE 21 21 10 WHITE X 30 BLACK X 30 WHITE X 24 BLACK X 30 BLACK X 30 BLOWER AIR ELEMENT BLAC...

Страница 17: ...InterMetro Industries Corporation hereinafter referred to as Seller warrants to the 10 17 15...

Страница 18: ...elect Online Warranty Registration to register electronically FOLD HERE DO NOT DETACH 16 CUSTOMER INFORMATION 1 Which one of the following best describes your establishment a Full Service Restaurant b...

Страница 19: ...WILL BE PAID BY INTERMETRO INDUSTRIES CORPORATION ATTN CUSTOMER SERVICE P O BOX A WILKES BARRE PA 18705 9968 STAPLE HERE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL F I R S...

Страница 20: ...THIS PAGE IS KEPT INTENTIONALLY BLANK...

Страница 21: ...h Washington Street Wilkes Barre PA 18705 For Product Information Call 1 800 992 1776 Visit Our Web Site www metro com L01 425 Rev G 10 17 Information and specifications are subject to change without...